Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T22CM05071
Parcel: 117022920

Address:
612 E 1ST ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - T22CM05071
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/18/2024 Fire New Construction NOT REQUIRED
07/17/2024 Site Engineering NOT REQUIRED
07/22/2024 Site Landscape NOT REQUIRED
07/22/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
06/24/2024 Residential Building REQUIRES RESUBMIT T22CM05071
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

Provide a response letter on separate file with submitting the updated construction plan set.

STRUCTURAL PLANS:

1. Provide roof framing plans showing beam and rafter sizes with 2018 IRC prescriptive compliance or provide an Arizona professional stamped plan set showing performance compliance with wind loading conditions, R301.1.
2. Field welding (detail #1/A004) requires a special inspection request form for review with the permit plans, R109.2. Provide a certified inspector seal on the form found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Inspections

ELECTRICAL PLANS:

1. Show any alterations or additions.

OUTDOOR LIGHTING CODE

1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
07/08/2024 Site Zoning REQUIRES RESUBMIT PDSD Zoning Review Section

PROJECT: T22CM05071
612 E 1ST ST. - HR-2
Porch Additions (3rd Review)

TRANSMITTAL DATE: July 8, 2024

COMMENTS: Resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1. COMMENT: This site is located in the HR-2 zone (UDC 4.7.9). Historic Review is required. Below is the link for the historic application. Please contact Jodie Brown (jodie.brown@tucsonaz.gov) or Michael Taku (michael.taku@tucsonaz.gov). Zoning can not approve until the historic review has been approved.
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Historic-Preservation

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
06/14/2024 PDSD Application Completeness REVIEW COMPLETED