Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T22CM04718
Parcel: 14118610C

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - T22CM04718
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/26/2023 Bldg Permits - Post Review PENDING ASSIGNMENT Shared Studio Session on T22CM04717 for permits T22CM04717-25
04/17/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Shared Studio Session on T22CM04717 for permits T22CM04717-25

Activity Number: T22CM04717/BLDG A,T22CM04718/BLDG B,T22CM04719/BLDG C, T22CM04720/BLDGD,T22CM04721/BLDG E, T22CM04722/BLDG F, T22CM04723/BLDG G T22CM04724/BLDG H, T22CM04725/CLUBHOUSE

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Conditionally Approved
NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances.


BUILDING REVIEW COMMENTS:
Approved


MECHANICAL REVIEW COMMENTS:
Conditionally Approved
1. You say all ducts are below the horizontal fire rated floor/ceiling assembly, and yet you are installing a fire damper in the kitchen exhaust, why, please clarify and be clear, are all the ducts below the fire rated ceiling assembly? sheet M1.1 (IMC2018,106.3.1) Complied
2. Is the bathroom exhaust duct below the horizontal fire rated ceiling assembly and if it is why isn't the kitchen duct below the ceiling? sheet M1.1 please be clear (IMC2018,106.3.1) Complied
Approved/subject to field approval


ELECTRICAL REVIEW COMMENTS
Approved


PLUMBING REVIEW COMMENTS:
Denied
Second Plumbing Review:
1). OK
2). OK Subject to Field Inspections--Civil utility piping plan pages as shown on Plan page T1 sheet index need to be supplied to do a complete plumbing review - IPC 106.3.1 **Plan page T1 states these pages under separate review**
3). OK Subject to Field Inspections--Landscape plan sheets as shown on plan page T1 sheet index need to be supplied to do a complete plumbing & Gas review. -IPC 106.3.1**Plan page T1 states these pages under separate review**
4). SAME- plan page D1.1 BBQ Ramada plan sheet is missing. -IFGC 106.3.1 **Response states propane tanks to be shown, could not locate this info**
5). OK
6). SAME- Maintenance Bldg. roof plan on A4.1 needs to illustrate the required secondary scuppers. -IPC 1106.5 & 1108
7). SAME-add Maintenance Bldg. scupper sizing calculations to plan page A4.1- -IPC 1101.7, 1106.1 , 1108.3
8). SAME-Add Maintenance Bldg. secondary scupper detail to plan page D4 - IPC 106.3.1 ** PLAN PAGE D4 NOT SENT**
9).OK- Add grease interceptor for kitchen sink located in assembly occupancy on plan page P1.4 -IPC 1003.1 ** OK Subject to inspection & local utility authority**
10). OK
11). OK
12).OK
13). OK
14). SAME-Add the underground gas piping piping types or method for the gas lines to the spa, pool, bbq on plan page P1.3 or MP 1.1-IFGC 404.11 **MP1.1 not sent as stated in response narrative**
15). SAME-Provide gas piping illustrations for the continuation of the gas lines to the spa, pool, bbq as stated on plan page P1.3 -IFGC 106.3.1
16). SAME-Add gas equipment schedule with manufacturer names & model numbers of the pool heater, spa heater, bbq, to plan page P4.2 -IFGC 301.3, 305.1 ** response states see pool plans, pool plans not included**
17). SAME -Add a gas piping roof attachment detail to plan page P3.1 -IFGC 404.9, 407.2 ** Plan page P1.3 states gas up thru roof to AC units, gas piping can't be supported by AC connection**
18). SAME- add piping material schedule to plan page P4.1 for gas, water, sanitary, storm -IPC 106.3.1**MP1.1 not sent as stated in response narrative**
19). SAME- GAS BBQ ramada on plan page A4.2 has overhead construction & will require a hood. -IFGC 623.1, 623.5


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
04/19/2023 Site Engineering REQUIRES RESUBMIT The permit cannot be approved until its associated development package, DP22-0105, has been approved.

Lianne Evans
lianne.evans@tucsonaz.gov
04/26/2023 Site Zoning REQUIRES RESUBMIT Shared Studio Session on T22CM04717 for permits T22CM04717-25

ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T22CM04717, T22CM04718, T22CM04719, T22CM04720, T22CM04721, T22CM04722, T22CM04723, T22CM04724, & T22CM04725 – DP22-0105
9070 S Houghton Rd – O-3
Multi-Family (1st Review)

TRANSMITTAL: April 25, 2022
This site is located in O-3 Zone (UDC 4.7.15), Multi-Family use is an allowed use in the zone (UDC Table 4.8-3).

1. Zoning has reviewed the building plans for compliance with DP22-0105. Zoning cannot approve the building plans until the DP is approved by all review agencies.

2. The address provided on the building plan application, 9070 S Houghton Rd, is not correct. Address 9070 S Houghton Rd is located in the Houghton Town Center located south of Old Vail Rd. Provide the correct address on the next submittal along with a revised application(s) with the next submittal.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
04/04/2023 PDSD Application Completeness REVIEW COMPLETED