Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T22CM04423
Parcel: 122153590

Address:
3229 E LINDEN ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - T22CM04423
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/02/2022 NPPO APPROVED
12/27/2022 Site Engineering APPROVED
01/11/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/11/2023 External Reviewers - Pima County Addressing REQUIRES RESUBMIT Unit number for proposed ADU is required. Please contact Pima County Addressing Phone # 520-724-9512, Email: Addressing@pima.gov
12/06/2022 Site Zoning REQUIRES RESUBMIT FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: T22CM04423
Sleeping quarters
3229 E LINDEN ST Zoning R-1

TRANSMITTAL DATE: December 6, 2022


COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


1.COMMENT: As you are proposing to convert from non-habitable space to habitable space and the existing structure does not meet perimeter yard setbacks to the west property line a neighbor’s setback waiver or Design Development Option (DDO) will need to be processed and approved to reduce the setback. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 10’-0” the required perimeter yard setback from the proposed accessory structure to the west property line is 6’-9”, the proposed setback is 2’-0”. At a minimum, a neighbor’s setback waiver is required to reduce the perimeter yard setback. To secure this waiver the following text shall be provided on the plot plan and be signed and dated by the owner of the property to the west:
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

If you are unable to secure the neighbor’s setback waiver a Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://tdc-online.tucsonaz.gov/#/ using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.



If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
12/02/2022 PDSD Application Completeness Express REVIEW COMPLETED
12/15/2022 Residential Building REVIEW COMPLETED