Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - T22CM03945
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/16/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
05/09/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: T22CM03945 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. Sheet G003: This page still states that an automatic sprinkler system will not be provided. The comment response letter stated that this language would be corrected. It has not been corrected. Additionally, the deferred/separate submittal list does not include the sprinkler system. Also, the section provided on G-003 does not apply to this project as it only applies to S-2 occupancies. It appears that these corrections have not been corrected. Permit will not be issued until this page is corrected. MECHANICAL REVIEW COMMENTS: Conditionally Approved Approved/subject to field approval ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Denied Third Plumbing Review: 1). OK 2).OK 3). OK 4). OK 5). SAME- water heater detail #11 on plan P-500 shows floor mounted installation, all other plumbing pages show elevated water heater. Plan pages need to correlate if elevated show support requirements & add pan to detail #11. -IPC 106.3.1 , 504.7 ** detail on P500 still shows floor mount water heater**(None of the 3 submitted plan sets sheet's page P500 show an elevated WH detail as shown in designer's response narrative. , all three show floor mounted detail, please add the detail to p500 that was displayed in the response narrative ) If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
05/16/2023 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
05/09/2023 | Site Zoning | REQUIRES RESUBMIT | REVIEW TRANSMITTAL FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM03945 Building Plans (3rd Review) 4711 E VALENCIA RD Zoning PAD-21 TRANSMITTAL: May 9, 2023 1. Zoning has reviewed the building plans for compliance with the associated unapproved Development Package DP22-0147. Zoning cannot approve the building plans until the DP is approved. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
04/20/2023 | PDSD Application Completeness | REVIEW COMPLETED |