Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T22CM03770
Parcel: 12902087A

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - T22CM03770
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/16/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
10/16/2023 Commercial Electrical REQUIRES RESUBMIT Please address the electrical plan review comments and provide a written response.

Provide plans and evidence on the plans that the proposed exterior lighting fully complies with the Outdoor Lighting Code (OLC). See section 104 for plan submittal requirements.

1. Provide site lighting plans with the following information on the plans;

(a) Cloud all changes in the luminaire schedule

(b) The luminaire schedule shows the replaced pole mounted luminaires at 25+ feet (36” pole base) above grade on poles adjacent to residential property. Verify compliance sections 104.2.1(1), (2), (3). OLC.

(c) The luminaire schedule, lumen calculations, and site lighting plans do not correlate (Delta 7) . Please clarify and revise the plans to correlate. For example; The flag Pole luminaires are not accounted for in the lumen calculations.

2 See table 401.1, lighting area and option and indicate this information in the lighting site plan

4 Provide calcs for total lumens allowed and total lumens proposed per acre including existing, for Full Cut Off and Unshielded per table 401.1.

Why does the total unshielded lumens exceed the allowable? Please clarify.

5 Indicate whether or not a special inspection is required per sec. 104.2.2, and 106.2. If a special inspection is required, provide the Special Inspection Certificate with the first Registrant seal provided by the Special Inspector.

6 Specify any exceptions used.

7 Curfew lighting controls (Unshielded lighting) shall comply with section 403, OLC.

8 Provide complete compliance with the 2018 IECC for the exterior lighting.

Do not confuse the Outdoor Lighting Code with the IECC.

Ref; 2017 NEC, 2012 Tucson/Pima County Outdoor Lighting Code (OLC), 2018 IBC sec 107.2.1. 2018 IECC.
09/20/2023 PDSD Application Completeness REVIEW COMPLETED