Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - T22CM03715
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/27/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/27/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: T22CM03715 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Approved Reason: Date Completed : 5/31/2022 2:46:58 PM Building(B) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 6/25/2023 7:20:30 AM 1. Sheet A-1 structural plan shows new walkable ceiling structure but does not provide section showing the walkable height and method to access the mechanical units. Show at what height are the wall mounted mechanical unit with factory bracket in section. 2. Sheet A-1 does not show method and space of mechanical appliance access. 2018 IBC 306 requires “access to appliances or HVAC system components that utilize energy shall be accessible for inspection, service, repair and replacement without disabling the function of a fire-resistance-rated assembly or removing permanent construction, other appliances, venting systems or any other piping or ducts not connected to the appliances being inspection, serviced, repaired or replaced. A level working space not less than 30 inch deep and 30 inches wide shall be provided in front of the control side to service an appliance.” 3. Electrical sheets show double doors at grow room but A-1 and M-1 indicate single door. Coordinate drawings. Closed and open corridor do not match either. Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 6/25/2023 9:39:00 PM This mechanical review was approved on 5/18/2023 no cause for action Electrical(E) Reviewer Ron Ross rross@safebuilt.com Conditionally Approved Reason: Date Completed : 6/27/2023 4:31:54 PM Electrical Review By: Ron Ross PE Approved with comment below E6.1: Panel A1 circuit breaker 2 is undersized for continuous lighting load. Upsize CB or reduce load for IFC set. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 10/9/2022 9:01:57 PM Fourth Plumbing Review: OK Subject to field Inspections 1). OK- Donor sink water piping still not protected, needs to connect before backflow preventers same as the restrooms & drinking fountain are currently shown - OR if this sink is part the grow process add signage above - IPC 608.9.1 - OK Subject to Field Inspections 2 thru 4 OK 5). OK 6). OK 7). OK 8). OK - Field verify Planter table drain P-traps 9). OK - Self Contained eye wash station 10) OK |
||
06/22/2023 | PDSD Application Completeness | REVIEW COMPLETED |