Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - T22CM03546
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/24/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
04/10/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: T22CM03546 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Conditionally Approved Approved/Subject to field approval ELECTRICAL REVIEW COMMENTS Conditionally Approved E-4.1 ONE LINE DIAGRAM - WEST SERVICE: Keynote 5 calls out for a 400 amp panel vs MCB and dedicated note ‘SLW’ calls out for this panel as 600 amps. Correct/coordinate panel schedule with One Line. ES-1.3 PARTIAL ELECTRICAL SITE PLAN: No keynote #11 provided. ESD-1.1 PARTIAL ELECTRICAL SITE DEMOLITION PLAN: Missing Keynote #3 PLUMBING REVIEW COMMENTS: Denied Second Plumbing Review: 1). SAME-Lavatories need to be in the same room as the toilets- IPC 405.3.2, Update all affected pages 2). SAME -There need to be the same number of lavatories as there are toilets. -IPC 403.1.3, Update all affected pages 3). SAME-Drinking Fountain on plan page L-1.10 can't receive storm water & drinking fountain must connect to sanitary. -IPC 301.3 , 1101.3 ** Or Provide Approval letter from Building Official Allowing discharge to earth as shown** 4). SAME-Provide Civil utility piping for continuation of sewer & water services -IPC 106.3.1 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
04/24/2023 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
04/21/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: T22CM03546 Columbus Park (2nd Review) 3495 W EL CAMINO DEL CERRO Zoning RX-1 TRANSMITTAL DATE: April 21, 2023 1. COMMENT: Zoning has reviewed the building plan for compliance with DP22-0127 and although it appears that the building plans match the DP Zoning cannot approve the building plans until the DP is approved. If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov. |
||
03/28/2023 | PDSD Application Completeness | REVIEW COMPLETED |