Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - T22CM02966
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/07/2023 | Site Engineering | APPROVED | |||
05/18/2023 | Historic | NOT REQUIRED | Property located in Pie Allen National Register Historic District which is not a Historic Preservation Zone. | ||
06/08/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/08/2023 | Residential Building | REQUIRES RESUBMIT | Provide updated construction plans with changes for addressing all comments listed on the INFO sheet. Relocate the INFO sheet from the construction plan set into a separate file submitted file. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. GFCI protected, E3902.6. Show receptacle outlets at each kitchen counter space wider than 12” with no point along the wall line more than 24” from a receptacle outlet, E3901.4.1. Show receptacles within 2’ of counter edges or corners and no more than 4’ apart. |
||
05/16/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM02966 938 E 8th St - R-2 New ADU (4th Review) TRANSMITTAL: May 16, 2023 This was not addressed. Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. This comment was not addressed. Based on a lot size of 50’ x 150’ the total lot square footage is 7,500 sq. ft. The plans show a total of building sq. ft. & parking of 2,675.48 sq. ft. for a lot coverage of 35.7%. The lot coverage calculation is not correct and should include all vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved. See UDC Article 6.4.3.B.3.b. 2. This comment was not addressed. The parcel dimensions show on the plan are not correct. Per the Rieckers Addition final plat recorded in Book 3 Page 127 the lot size is 50’ x 150’. Provide parcel dimensions on the plot plan 3. This comment was not addressed correctly. Based on Paving plan I-400 found at: https://www.tucsonaz.gov/apps/maps-and-records/construction-plans/details/I-400, the distance from centerline of 8th to curb is 19.6’ and from curb to property line is 20’. Provide a dimension from the centerline of 8th St to the face of curb and from the face of curb to the north property line. 4. This comment was not addressed correctly. Based on Paving plan I-836 found at: https://www.tucsonaz.gov/apps/maps-and-records/construction-plans/details/I-836, the distance from centerline of Caddie to the property line is 21.5’. Provide a dimension from the centerline of Caddie St to the south property line. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
05/05/2023 | PDSD Application Completeness | REVIEW COMPLETED | |||
05/05/2023 | Site Landscape | REVIEW COMPLETED |