Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - T22CM02795
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/19/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/19/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0323-03671 (901 N BARBARA WORTH TUCSON, AZ 85710) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Electrical plans, Sheet E1.1: 1. Updated plans show an “Existing” 200A rated panel with a 125A main breaker. The Original plans showed a service upgrade to 200A, so with the service upgrade being removed, verify that the existing panel is 200A rated. 2. Show an updated 120% bus bar calculation for the existing Main Service Panel, NEC 705.12. Show the MSP is protected accordingly. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 03/29/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |