Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T22CM02472
Parcel: 129120080

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - T22CM02472
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/24/2023 Residential Building APPROVED
10/26/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/26/2023 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Nathan Herrera
Planner

PROJECT: T22CM02472
Address: 1115 E 26th St. Tucson, AZ. 85713
Parcel: 129-12-0080
Zoning: R-2
Existing Use: Single Family Residence
Project Description: Second Unit

TRANSMITTAL DATE: 10/26/2023

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence and additional unit is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

1. COMMENT: Per UDC Article 6.3-2.A, the required setback in the R-2 zone is the greater of 6 feet or 2/3 the height of the proposed building wall.

Per UDC Article 6.4.4.A, “…height is the vertical distance measured from the design grade elevation…”

Per UDC Article 6.4.5.B.2, “A vertical structural member(s) (i.e., post, column, dormer wall) supporting a roof extension from the principal structure is considered a wall for applying perimeter yard requirements.”

Provide a dimension from the design grade elevation to the highest point of the building wall supporting the roof extension per the above standard.

Based on the height of the overhang of 9 feet and a design grade level of -8”, the required setback will be greater than the 6’ shown on the plan.

Clarify the proposed setback on the next submittal.

2. COMMENT: Per UDC Article 6.6.3.C, “Detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line.”

The property is located in the R-2 Zone and is eligible for a 2nd unit that does not have to follow the above ADU standard. On the next submittal change the references from an ADU to a Second Unit.

3. COMMENT: Provide a Lot Coverage Calculation. Per UDC Article 6.4.3., Lot Coverage includes the areas of a lot covered by buildings, storage areas, and vehicular use areas.
RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised residential building permit along with a detailed response letter, which states how all Zoning Review Section comments were addressed. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf
If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@TucsonAZ.gov or 520-837-4894.
10/09/2023 PDSD Application Completeness Express REVIEW COMPLETED