Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T22CM02443
Parcel: 113111260

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - T22CM02443
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/08/2023 Zoning Modifications - DDO APPROVED
08/08/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
04/18/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T22CM02443
1609 E Waverly St - NR-1
Rebuilding Shade Structure & Adding Storage Container (4th Review)

TRANSMITTAL: March 18, 2023

COMMENTS: the following comments are relative to an application for NPZ Review (UDC 5.10.3).

Until the following reviews are approved Zoning cannot approve this plan.

This site is located in the NR-1 zone (UDC 5.10.3). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 – 9.

1. This comment was not addressed. Contact Maria Gayosso, email Maria.Gayosso@tucsonaz.gov, phone (520) 837-6972 or Nicholas Martell, email Nicholas.Martell@tucsonaz.gov, phone (520) 837-6933 for submittal requirements. Prior to zoning approval an NPZ review and approval is required. Owner is proposing to rebuild existing shade structure and add a storage container. The property fronts Waverly Street. As a residential plot plan was not provided it is not clear what the proposed setbacks to either structure is.

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

The required perimeter yard setbacks for the NR-1 zone interior property lines is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A.
2. Based on a height of 8’-0” the required perimeter yard setback from the proposed shade structure to the east property line is 6’-0”. The Design Development Options (DD0) must be approved prior to approval of this plan.


If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
06/21/2023 Design Review REVIEW COMPLETED Design Professional review 6-19-23 determined no NPZ application required.


Bernard Buford <bbuford@architecturecompany.net>
Gabriel Sleighter
Maria Gayosso;Fe Tom <rfetom@architecturecompany.net>
Gabriel,

Is this still an active case? The Property Research Online for this case shows the Design Review as N/A. Do you still need a Design Professional determination from Fe?

Fe and I found this email and reviewed the attached revised plan set. There was an earlier email where Maria Gayossa stated that the house is a "contributing" structure, but the shade structure is "non-contributing". In reviewing the Site Aerial Photos, it is clear that the new shade structure is "not visible" from the street due to the large trees, metal panel fencing and parked vehicles located between the East property line and the East façade of the house that block any view of the new shade structure located in the backyard (Also, see the photo looking South towards Waverly on Page 14 of the plan set)

To further confirm that the new shade structure is "not visible", I drove by the property and took the attached photo looking North down the East property line where the new shade structure is located in the backyard. As you can see, any view of the new shade structure from the street is clearly blocked.

Since this project is not visible from a street, in accordance with Step 1 of Chapter 1: Pre-Submittal Guidelines of the Jefferson Park NPZ Design Manual, this project does not meet all of the criteria that would require this project to comply with the Design Manual requirements. Therefore, this project does not require a full NPZ review, but it must still be submitted to PDSD for Site and Building Permit approvals.

Let us know the status of this application and if you require anything further.

Sincerely,

Bernard Buford | Project Designer
the architecture company
2625 N. Silverbell Road | Tucson, AZ | 85745
T 520-622-4506 | C 520-991-3951
www.architecturecompany.net
03/20/2023 PDSD Application Completeness REVIEW COMPLETED