Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - T22CM02296
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/13/2022 | NPPO | APPROVED | |||
| 12/13/2022 | Site Engineering | APPROVED | |||
| 01/09/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/09/2023 | Residential Building | REQUIRES RESUBMIT | Items built without permit may require alteration or improvement for code compliance with the 2018 IRC, R105. Show the as-built Ramada construction plans with necessary alterations for achieving 2018 IRC code compliance. The site plan shows the Ramada placed along the west property line. The Ramada roof may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection. Provide compliance with R302.1 (City of Tucson Amended) by removing the Ramada roof within 3 feet to the west property line or provide a complete (fire spread wall) barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2). |
||
| 12/28/2022 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM02296 5710 E 32ND ST Zoning R-1 TRANSMITTAL DATE:December 28, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: In the R-1 ZONE, a single-family residence is subject to Use Specific Standards 4.9.7.B.7 which states “For any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom. For all single-family dwellings in the R-1 zone with five or more bedrooms, and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom , all parking spaces must be located on-site , either in a side or rear perimeter yard . Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used. A bedroom is defined as The term bedroom includes all of thefollowing: 1) Any room that is designated as a bedroom;2) Any enclosed room that has a minimum area of 60 square feet and has an accessible opening to the exterior of the building in compliance with the International Building Code (IBC),whether termed a studio, family room, study, den, bonus room, or any other name, except for a living room, dining room, kitchen , and bathrooms; and 3) Any room designated as a bedroom for the purpose of any other code requirement, see UDC Article 11.4.3 Definitions -B. That all said with the proposed addition this SFR will have 5 bedrooms. Clearly demonstrate this the above requirement is met. Comment: Provide a floor plan for the existing residence on the plan so that Zoning can verify if the requirements of UDC Article 4.9.7.B.7 are applicable to this project. Provide in the link below is a floor plan example on page 3 https://www.tucsonaz.gov/files/pdsd/pdfs/Addition_Sample.pdf 3.COMMENT: Clearly show everything on site. Based on current aerial photos there is an addition on the rear and front of the house. Additional comments may be forth coming. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 12/13/2022 | PDSD Application Completeness Express | REVIEW COMPLETED |