Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - T22CM01601
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/28/2022 | Commercial Plumbing | APPROVED | |||
10/28/2022 | Site Engineering | APPROVED | |||
11/29/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
11/04/2022 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: T22CM01601 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Denied Due to the change of occupancy submitted corrections dated on 6/17/2022 are cancelled see new corrections below 1. Provide fire dampers where ducts penetrate the 1 hour fire rated horizontal assembly between floors (IMC2018,607.6.1) 2. Provide ventilation calculations (IMC2018,403.3.1.1.1) 3. Kitchen exhaust duct shall be protected in an approved when penetrating the horizontal fire rated assembly in an approved manner, a chase is not acceptable and there is no fire damper allowed in kitchen exhaust ducts penetrations (IMC2018,505.505.5) 4. Provide firestop system for dryer and bathroom duct penetration's equal to astm e 119 or ul 263 (IMC2018,607.6.1) 5. Provide ceiling radiation dampers for bathroom exhaust fans mounted in ceiling (IMC2018,607.6.1) ELECTRICAL REVIEW COMMENTS Conditionally Approved E7.0 Feeder Diagram: Need to upsize AL conductors for PNL E. PLUMBING REVIEW COMMENTS: Denied Third PLUMBING REVIEW: 1 THRU 3 OK 4). SAME-Add the manufacturer name & model number info of the gas appliance that is to be installed in unit 4's fireplace to plan page P2.1 or P4.2 to show that it complies with -IFGC 303.3 #1 , 304.5, & 602 ** NOT SHOWN ON ANY OTHER PAGES AS STATED ON RESPONSE SHEET** 5 THRU 13 OK 14). OK If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
11/29/2022 | Historic | REQUIRES RESUBMIT | Please submit the required documents noted in the Special Districts application via TDC Online. Information on the proposed AC units and new skylights should also be included in the plan set. | ||
11/01/2022 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM01601 TI Multi Family 343 S Scott Ave Zoning HC-3 TRANSMITTAL DATE:‎November 1, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Zoning has reviewed the building plan for compliance with DP22-0225, Zoning cannot approve the building plans until the DP is approved. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
11/16/2022 | Fire New Construction | REVIEW COMPLETED |