Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - T22CM00103
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/23/2024 Site Engineering NOT REQUIRED
04/25/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/09/2024 Residential Building REQUIRES RESUBMIT T22CM00103
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Facilitate a shorter back check time: provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes.

SITE PLAN:

1. Clarify keynotes 10 & 11. The details seem to show new construction at location 11 rather than 10 as noted.
2. Identify any utility lines requiring upgrade or replacement, R106.1.1.

PLANS:

1. Show a ½” gypsum board (garage side) on all walls common to the garage and dwelling or other fire rated product in compliance with R302.6.

SECTIONS - DETAILS:

1 Show a complete cross-section detail of the altered exterior wall, R106.1.1. Show the minimum 12” x 12” continuous #4 rebar reinforced footing, R403.1. The existing wall cannot support the proposed loads if the foundation is undersized.
2 Show a means of preventing roof runoff from reaching the neighboring property, R106.1.1.

ELECTRICAL PLANS:

1. Garage Branch Circuit: a separate (dedicated) GFCI 20-amp branch circuit required for receptacles in an attached garage and detached garages with service, E3703.5. A receptacle is required at each vehicle bay not more than 5.5 feet above the floor, E3901.9. Additional receptacles are optional.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
04/25/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T22CM00103
1811 S Carthage Pl – Rx-2
Convert Carport to Garage and Extend Garage (2nd Review)

TRANSMITTAL: April 25, 2024

This site is located in the RX-2 zone (UDC 4.7.6). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-3).

The following comments were not addressed.

1. As you are proposing to eliminate the required 20’-0” perimeter yard setback to the northeast property line a Board of Adjustment for Variance will be required to be submitted and approved prior to approval of this plan.

Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf. The Board of Adjustment is a separate submittal from this building plan and is submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. Contact of the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov.


COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment (UDC Section 3.10.1).

1. The minimum setback is twenty feet (20) facing each interior property line (Table 6.3-1.A). Proposed perimeter yard setback from the proposed garage to the northeast property line is 0’-0”.

Additional Comments
2. Based on current aerial photos there is some type of detached accessory structure located near the rear corner of the of the proposed garage enclosure. Show this structure on the plan.

3. The property dimensions shown on the plot plan are not correct. Review the Discovery Ridge final plat found at: https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=25018, and provide the correct dimensions.

4. Remove the setback lines called out under Keynotes 2, 3, & 4, from the plan as none are shown correctly.


If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.