Review Details: RESIDENTIAL NEW DWELLING v.5
Permit Number - T21CM09659
Review Name: RESIDENTIAL NEW DWELLING v.5
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/19/2023 | Site Zoning | APPROVED | |||
| 09/19/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/14/2023 | Residential Building | REQUIRES RESUBMIT | T21CM09659 R1 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: Clarify if the Guest House structure is a sleeping quarters (without kitchen) or an Accessory Dwelling Unit (ADU) which has a maximum size of 1000 SF and requires collection of impact fee. Verify all requirements with the Zoning Section. Each dwelling unit with kitchen requires a separate Pima County assigned street address, R319. Notate each dwelling address on the site plan (or remove cooking appliances). Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. SITE PLAN: 1. Show the buildings and water and sewer lines from property line to proposed building, R106.1.1. Identify the utility lines requiring upgrade or replacement. PLANS: 1. Notate a cool (white) roof finish as required by the ADU provisions. 2. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. Include all threshold conditions for a route from the exterior into the living space. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Update keynote 8.6. ELECTRICAL PLANS: 1. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. Show circuit #10 on the plan. 2. Protect extended branch circuits with combination type arc-fault circuit interrupters, or an AFCI type receptacle at the first outlet on the branch circuit, E3902.17. Update note #K by removing “bedroom”. OUTDOOR LIGHTING CODE 1. Update the Outdoor Lighting Calculation; show the unshielded limit for area E3 with 11,000 lumens per acre. This was changed with the latest code addition. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. Please contact the plans reviewer if you have any questions: Ken Van Karsen (520) 837-4912 PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 09/14/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 08/28/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |