Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T21CM06229
Parcel: 10605019B

Address:
3707 N ORACLE RD

Review Status: Requires Resubmit

Review Details: BUILDING DEFERRED SUBMITTAL REVIEW v.1

Permit Number - T21CM06229
Review Name: BUILDING DEFERRED SUBMITTAL REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/27/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/27/2024 Other Inspection Reports (Deferred Submittal) Express REQUIRES RESUBMIT BOLT INSTALLED INCONCRETE:
ACTIVITY NO. T21CM06229
ADDRESS/PARCEL: (3707 N ORACLE RD TUCSON, AZ 85705)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.
COMMENTS:
1. We went through your 36 page report twice and we could not find a Bolt Installed in Concrete special inspection. Either pluck those pages from the 37 page report and submit it individually or have the Project Engineer in Charge write a letter to the effect that Bolts in concrete were not used on this project.
2. Please note that we did find an Epoxy Anchor special inspection using Simpson XP-N and HTT4 holdowns which was used to result the Epoxy Anchors special inspection.
3. See other special inspection.
4. Please resubmit.
06/27/2024 Other Inspection Reports (Deferred Submittal) Express REQUIRES RESUBMIT SHOP DRAWINGS FOR PLYWOOD WEB JOISTS:
ACTIVITY NO. T21CM06229
ADDRESS/PARCEL: (3707 N ORACLE RD TUCSON, AZ 85705)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.
COMMENTS:
1. See other condition.
2. See other condition.
3. The Michael Wilda of Simply Structural letter is not attached/submitted. Please upload this aforementioned letter for processing.
4. Please resubmit.
06/26/2024 PDSD Application Completeness Express REVIEW COMPLETED
06/26/2024 Welding Inspection (Deferred Submittal) Express REVIEW COMPLETED Weld Reinforcing Steel.