Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - T21CM05527
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/27/2023 | Site Zoning | APPROVED | Shared Studio Session 783-877-878 Master Permit T21CM05449, T21CM05523, T21CM05524, T21CM05525, T21CM05526, T21CM05527, T21CM05528, T21CM05529, T21CM05530, T21CM05531, T21CM05532, T21CM05533, T21CM05534, T21CM05535, T21CM05536, T21CM05537, T21CM05538, T21CM05539, TC-COM-1122-00133, TC-COM-1222-00257, TC-COM-1222-00258, TC-COM-1222-00259 | ||
| 08/21/2023 | Water - PDSD | APPROVED | Shared Studio Session 783-877-878 Master Permit T21CM05449, T21CM05523, T21CM05524, T21CM05525, T21CM05526, T21CM05527, T21CM05528, T21CM05529, T21CM05530, T21CM05531, T21CM05532, T21CM05533, T21CM05534, T21CM05535, T21CM05536, T21CM05537, T21CM05538, T21CM05539, TC-COM-1122-00133, TC-COM-1222-00257, TC-COM-1222-00258, TC-COM-1222-00259 | ||
| 08/21/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | Shared Studio Session 783-877-878 Master Permit T21CM05449, T21CM05523, T21CM05524, T21CM05525, T21CM05526, T21CM05527, T21CM05528, T21CM05529, T21CM05530, T21CM05531, T21CM05532, T21CM05533, T21CM05534, T21CM05535, T21CM05536, T21CM05537, T21CM05538, T21CM05539, TC-COM-1122-00133, TC-COM-1222-00257, TC-COM-1222-00258, TC-COM-1222-00259 | ||
| 08/08/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 8/7/2023 6:10:48 PM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 8/2/2023 10:25:20 AM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 7/28/2023 7:23:26 PM Approved/subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 7/27/2023 4:58:49 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 8/1/2023 6:18:12 AM First Revised Plan Plumbing Review: 1). Clouded Site utility piping plans & landscaping plan pages Sheet 1 thru L-12 not provided as shown on plan page T1 -IPC 106.3.1 (needs to correlate with the revised plumbing pages) 2). FS1 on plan page P1.9 can't be located at exterior . -IPC 1101.3 ( suggest relocate FS1 to interior or delete & pipe condensate to mop sink) 3). The required bottlless water dispenser P6c is not shown on plumbing piping plan page P1.7, but is shown on plan page P4.2 fixture schedule which shows a drain & water connection. -IPC 106.3.1, Tucson IPC amendment 410.4 4). The P1 toilets on sanitary riser detail; #1 on plan pages P2.2, P2.3 are not vented properly -IPC 901.2.1 5). The P1 toilets on sanitary riser detail; #1, #2, #4 , #5 & #6 on plan page P2.1 are not vented properly -IPC 901.2.1 |
||
| 07/27/2023 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
| 07/26/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 07/25/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | Shared Studio Session 783-877-878 Master Permit T21CM05449, T21CM05523, T21CM05524, T21CM05525, T21CM05526, T21CM05527, T21CM05528, T21CM05529, T21CM05530, T21CM05531, T21CM05532, T21CM05533, T21CM05534, T21CM05535, T21CM05536, T21CM05537, T21CM05538, T21CM05539, TC-COM-1122-00133, TC-COM-1222-00257, TC-COM-1222-00258, TC-COM-1222-00259 |