Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - T21CM05524
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/11/2024 | Site Engineering | NOT REQUIRED | Shared Studio Session. Master Permit T21CM05449 with reviews to be reflected on T21CM05523, T21CM05524, T21CM05525, T21CM05526, T21CM05527, T21CM05528, T21CM05529, T21CM05530, T21CM05531, T21CM05532, T21CM05533, T21CM05534, T21CM05535, T21CM05536, T21CM05537, T21CM05538, T21CM05539 | ||
| 10/11/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | Shared Studio Session. Master Permit T21CM05449 with reviews to be reflected on T21CM05523, T21CM05524, T21CM05525, T21CM05526, T21CM05527, T21CM05528, T21CM05529, T21CM05530, T21CM05531, T21CM05532, T21CM05533, T21CM05534, T21CM05535, T21CM05536, T21CM05537, T21CM05538, T21CM05539 | ||
| 10/04/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Shared Studio Session. Master Permit T21CM05449 with reviews to be reflected on T21CM05523, T21CM05524, T21CM05525, T21CM05526, T21CM05527, T21CM05528, T21CM05529, T21CM05530, T21CM05531, T21CM05532, T21CM05533, T21CM05534, T21CM05535, T21CM05536, T21CM05537, T21CM05538, T21CM05539 Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Approved with Comments Reason: Date Completed : 8/7/2023 6:10:48 PM Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 8/2/2023 10:25:20 AM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Approved with Comments Reason: Date Completed : 7/28/2023 7:23:26 PM Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 7/27/2023 4:58:49 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 10/3/2024 9:09:10 PM Second Revised Plan Plumbing Review: comments 2 & 3 remain Resolved-1). Clouded Site utility piping plans & landscaping plan pages Sheet 1 thru L-12 not provided as shown on plan page T1 -IPC 106.3.1 (needs to correlate with the revised plumbing pages) Un-resolved-2). FS1 on plan page P1.9 can't be located at exterior . -IPC 1101.3 ( suggest relocate FS1 to interior or delete & pipe condensate to mop sink) **Duct work not an approved cover for floor sink & can still receive ground water** Un-resolved-3). Plan page P1.7: The required bottlless water dispenser P6c is not shown on plumbing piping plan page P1.7, but is shown on plan page P4.2 fixture schedule which shows a drain & water connection. -IPC 106.3.1, Tucson IPC amendment 410.4 **still missing drain & vent illustrations as stated on P4.2** Resolved-4). The P1 toilets on sanitary riser detail; #1 on plan pages P2.2, P2.3 are not vented properly -IPC 901.2.1 Resolved-5). The P1 toilets on sanitary riser detail; #1, #2, #4 , #5 & #6 on plan page P2.1 are not vented properly -IPC 901.2.1 |
||
| 09/27/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |