Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - T21CM02707
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/18/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/21/2023 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM02707 8516 E 3rd St – R-1 Attached Side Entry Garage (4th Review) COMMENT: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. These comment are still applicable Zoning acknowledges that the Design Development Option was processed and denied, Either construct the garage to meet the zoning requirements or the DDO will need to be appealed to by the Board of Adjustment, f. Provide a dimension from centerline of 3rd to the property line and from the property line to the curb. 1.Provide a dimension from the face of the garage to the property line COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). 2. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. 3. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 14’-4” the required perimeter yard setback from the proposed garage to the east property line is 9’-7”, proposed setback is 3’-2”. 4. The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). Based on a wall height of 14’-4” the required front street perimeter yard setback from the proposed side entry garage to the front street property line is 21’-6”, proposed setback at the northeast corner is 6’-10” and at the northwest corner is 4’-0” A Design Development Option (DDO) must be submitted and approved to reduce the required setback, DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 03/30/2023 | Zoning Modifications - DDO | REQUIRES RESUBMIT | A notice of intent to appeal the denial of DDO-23-10 has been received by Zoning Administration staff. An application to appeal the PDSD Director's decision of DDO-23-10 shall be applied for on the Tucson Development Center under application type "Appeal - Design Development Option." The application and associated fees shall be applied for and paid for by April 8 (30 days after the effective date of decision). Contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951 should you have questions regarding this transmittal. |
||
| 03/18/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 04/03/2023 | Site Engineering | REVIEW COMPLETED |