Review Date Reviewer's Name Type of Review Description Status Comments
07/22/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/22/2024 Commercial Building REQUIRES RESUBMIT Please revise plans to provide the following information listed below. The plans have been reviewed for ADA compliance. The following comments that need to be addressed. Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed.

1. General: A minimum number of dwelling units are required to have mobility features. Provide a room matrix that shows the accessible room calculations. Additionally, the rooms must be properly dispersed throughout the structure in accordance with 2018 IBC Section 1107.6.2.2.1 and 1107.6.2.2.2.
2. General: Provide within the site plans, drawings that clearly indicate the accessible routes within the site and site arrival points that connect the accessible parking to the accessible entrances that are in accordance with 2018 IBC Section 1104.1 and 1104.2.
3. General: Provide evidence of compliance that 60% of the public entrances are accessible in accordance with Section 2018 IBC Section 1105.1.
4. General: Provide evidence of compliance that at least one restricted entrance is accessible in accordance with 2018 IBC Section 1105.1.3.
5. General: No details have been provided regarding the required accessible units. Provide detailed floor plans for required accessible units that include accessible routes within the units as well as clear floor spaces in accordance with 2018 IBC and ANSI A117.1.

Please contact me if you have any questions about these comments.

Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov