Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - T21CM01303
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/29/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/29/2024 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. Sheet B1.1: Please amend plans to show a detail section through the kitchen sink/counter, to demonstrate the required Knee and Toe clearance. 2009 ICC A117.1 Section 306. Additionally, show the Knee and Toe clearance at the bathroom lavatory also. IBC 107.2.1 2. Sheet B1.1: Please amend plans to show the height of the sink shall be 34” maximum above the floor, measured to the higher of the rim or counter surface. 2009 ICC A117.1 Section 606.3. 3. Sheet B1.1: Please amend plans to show a folding seat in the roll-in shower, or alternatively for a fixed seat, provide a shower with a clear inside dimension of 60 inches minimum in width and 30 inches minimum in depth, measured at the center point of opposing sides. An entry 60 inches minimum in width shall be provided. 2009 ICC A117.1 Section 608.2.2.1, 608.2.2.3 4. Sheet B1.1: Please amend plans to provide the seat dimensions, and the clearances as described in 2009 ICC A117.1 Section 610.3.1 http://codes.iccsafe.org/content/icca117-12009comm/chapter-6-plumbing-elements-and-facilities#action-wrapper-9428549 5. Sheet B1.1: Please amend plans to note or otherwise indicate Showers shall deliver water that is 120°F maximum. 2009 ICC A117.1 Section 610.8.8 6. Sheet B1.1: Please provide section detail demonstrating roll-in-type shower compartments shall be 1/2 inch maximum in height in accordance with Section 303 2009 ICC A117.1 Section 608.6 7. Sheet B1.1: Please provide dimensions to demonstrate the controls and hand shower shall be located on the back 16 inches minimum and 27 inches maximum from the end wall behind the seat. The range of 16 inches to 27 inches (405 to 685 mm) from the seat wall will locate the controls so that they are in front of the seat and not above the seat, and at the same time be within reach of a person using the seat. 2009 ICC A117.1 Section 608.4.2 8. Sheet B1.1: Please show kitchen hood control/switches no higher than 44 inches above the floor. 2009 ICC A117.1 Section 308,309 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 08/28/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |