Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - T21CM01130
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/27/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/27/2023 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL Nicholas Martell, Principal Planner T21CM01130 (4th Review) Residential Addition March 27, 2023 The residential plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed. None of the previous comments have been addressed from prior reviews. Please use the following document as a checklist for plot plan requirements: coverage:https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf 1. Please provide the height of the unpermitted structure in the back yard. Be advised that if the structure exceeds 12' in height, a board of adjustment variance will be required for zoning approval. 2. The street setback measurements are incorrect. The measurements must be from the property line, as opposed to the back of the curb, as shown on the plans. Please provide the measurements from property line on the next submittal. 3. Zoning will be unable to determine the need for a Design Development Option (DDO) until the proper setback dimensions are added. Because the property is located on a corner lot, the required street setbacks are 20' on one side, and 10' on the other side. Please reach out to Mark.Castro@tucsonaz.gov for more information on the DDO application. 4. The 9'x16' shed does not meet setback requirements. This can be addressed through the DDO, or the setbacks can be waived by the neighbors at 434 N MEDFORD DR. If you opt for the neighbor waiver, please obtain a signature from the neighbor, and add the following note on the site plan: "“My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________” 5. A lot coverage calculation is required for this site. Please see the following template to calculate the coverage: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf 6. Add the legal description 7. Add the surrounding zoning. 8. More comments may be forthcoming. If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov |