Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T19CM08466
Parcel: 140191040

Address:
5451 S MORRIS CI

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.4

Permit Number - T19CM08466
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/07/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/14/2024 Residential Building REQUIRES RESUBMIT T19CM08466
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes.

Structures built without a permit may require alteration for building code compliance.

Provide a clear and concise construction plan set. Sample drawings for a wooden Carport are similar to the Porch Sample. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

SITE PLAN:

1. Show the electrical service panel and service line location, R106.1.1. Show the utility line requiring upgrade or replacement.
2. The roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the roof placed within 3 feet to the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2).

STRUCTURAL PLANS:

1. Provide a Roof Framing Plan showing the location and size of beams, headers, and rafters for supporting live and dead structural loads, R804.

SECTIONS - DETAILS:

1 Provide a complete cross-section detail with post to foundation and framing fasteners. Also, show roof sheathing type and size, R407.3 & R507.4.1.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
11/07/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Fernando García
Planning & Development Services Department – Zoning Review Section

PROJECT:
T19CM08466 – Residential Building
5451 S Morris Ci, Tucson, AZ 85706
Building Plan Review (1st Review)

TRANSMITTAL DATE: November 7, 2024

This site is located in the R-2 zone (UDC 4.7.9). A detached single-family dwelling is a permitted use in this zone.

1. (Comment) Please clarify scope of work. It appears that the existing carport was removed and this a permit for a new carport.

2. (Comment) The provided site plan does not meet minimum requirements.

Provide a site plan and elevation drawings that meet submittal requirements. See the page at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example for more information and examples.

An example of a complete site plan is the one provided for this site before. It can be viewed at https://pro.tucsonaz.gov/permitdetails/T20SA00027/. Scroll to the bottom of this page and click on the file labeled “DDO-20-07_PLANS AND ELEVATION.PDF”.

3. (Comment) The attached Design Development Option (DDO) application is dated 2020. A new, updated DDO application will need to be resubmitted using the measurement and setback information for the new carport.

SUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and elevations drawings with a detailed response letter, which states how all Site Zoning Review Section comments were addressed. Approved DDO for reduced front street setback.

For in-person assistance, visit the PDSD Public Service counter from 0800-1200 Monday to Thursday at 201 N Stone Av.

If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov. For faster review, provide email notice when resubmitted.
10/03/2024 PDSD Application Completeness Express REVIEW COMPLETED