Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: S22-072
Parcel: 10602303A

Address:
3802 N ORACLE RD

Review Status: Requires Resubmit

Review Details: LAND DIVISION/SUBDIVISION v.1

Plan Number - S22-072
Review Name: LAND DIVISION/SUBDIVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
Commercial Plumbing APPROVED
NPPO NOT REQUIRED block plat, existing sub
OK to Submit - External Reviewer PC Addressing NOT REQUIRED Email from: Nicholas Jordan
To: CDRC
11/01/2022

S22-072 Oracle Gateway Final Plat does not require review by Pima County Addressing.





Thank you



Nicholas Jordan

Site Review Project Manager - Addressing Official

Pima County Development Services Department

201 N Stone AV – 1st Floor

Tucson, AZ 85701

(520) 724-9623
CDRC Post Review PENDING ASSIGNMENT
Commercial Building REQUIRES RESUBMIT Provide details showing that buildings meet 2018 IBC requirements for separation of buildings or existing 2-hour fire wall where parcels and buildings intersect.
Juan Garcia
juan.garcia@tucsonaz.gov
Commercial Structural REQUIRES RESUBMIT Provide details showing that buildings meet 2018 IBC requirements for separation of buildings or existing 2-hour fire wall where parcels and buildings intersect.

Juan Garcia
juan.garcia@tucsonaz.gov
External Reviewers - Pima County Wastewater (RWRD) REQUIRES RESUBMIT A review is required and needed by RWRD, however will enter a "requires resubmit", so that that permit can move forward.
New Services/JOC REQUIRES RESUBMIT 1. The proposed final plat does not show existing 15’ public water easement created by DKT. 7807, PG. 1194 properly. It shows a “leg” of this existing easement running north in the northern portion of Lot 7 and then turning west and straddling the common lot line between Lot 1 and Lot 2, that isn’t shown on Tucson Water’s Plan No. 085-1986. Nor is it present in the legal description of the recorded easement. Please revise the proposed final plat as necessary to show existing 15’ public water easement created by DKT. 7807, PG. 1194 properly.
2. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
Site Engineering REQUIRES RESUBMIT 1. The reference in the title block for this final plat needs to be corrected. It reads subdivision of unsubdivided land, but this is a resubdivision of already subdivided land. Revise as needed.

2. Provide as separate document or on the plat revised and new cross access agreements within the new subdivision.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
Site Zoning REQUIRES RESUBMIT CDRC TRANSMITTAL



FROM: PDSD Zoning Review



PROJECT: Oracle Gateway Lots 1 through 7

FINAL PLAT (1st Review)

S22-072



TRANSMITTAL DATE: November 14, 2022



DUE DATE: December 07, 2022



COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

2-07.1.0 APPLICABILITY



Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as “plat” or “plats.”

A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder’s Office. The final plat is kept on file and becomes part of the permanent record for the subject site.



2-07.5.0 CONTENT REQUIREMENTS



2-07.5.1   General



COMMENT: 2-07.5.1.H - The subdivision case number, S22-072, assigned to this plat must be placed in the lower right corner of the plat next to the title block on all sheets.



COMMENT: Some type of cross access, cross parking agreement/easement is required for this project. Provide a copy of the recorded documents with the next submittal.



If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov.
CDRC Review Coordinator REVIEW COMPLETED
Fire New Construction REVIEW COMPLETED
OK to Submit - Engineering REVIEW COMPLETED
OK to Submit - Zoning REVIEW COMPLETED