| NPPO | APPROVED | Protect native plants on site, any removed must be replaced. | |||
| CDRC Post Review Express | PENDING ASSIGNMENT | ||||
| Final Plat Package Fast | PENDING ASSIGNMENT | ||||
| Commercial Building | REQUIRES RESUBMIT | 1) Demonstrate independent sewer access for each of the three lots. Juan Garcia juan.garcia@tucsonaz.gov |
|||
| Commercial Plumbing | REQUIRES RESUBMIT | For the purposes of having a water meter, a parcel is required to have a minimum width of 15-feet of frontage on a water main. An easement is not considered to be frontage. Show how lots 2 and 3 will be supplied with water. Reference: Tucson Water Remote Meter Policy, Number IV-B.08, dated 07/14/2009. | |||
| Commercial Structural | REQUIRES RESUBMIT | 1) Identify separate sewer access per proposed lot | |||
| New Services/JOC | REQUIRES RESUBMIT | 1. The proposed lot layout is not acceptable to Tucson Water. Proposed Lots 2 and 3 each have just 10’ of such frontage on Martin Avenue where the public water main is located. Tucson Water’s Remote Meter Policy requires each of the new parcels to have a minimum of 15’ of real property frontage onto a public street or water easement that contains a public water main. 2. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
|||
| Site Engineering | REQUIRES RESUBMIT | See Zoning & Tucson Water comments. Joshua Garcia joshua.garcia@tucsonaz.gov |
|||
| Site Zoning | REQUIRES RESUBMIT | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Paul Camarena PDSD Zoning Review Section PROJECT: 2743 N MARTIN AV Final Plat (1st Review) S22-071 TRANSMITTAL DATE: January 18, 2023 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as “plat” or “plats.” A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder’s Office. The final plat is kept on file and becomes part of the permanent record for the subject site. (Am. Admin. Directive, 5/14/2013) 2-07.3.0 SUBMITTAL TIMING Review of final plats is normally initiated after the tentative plat has been approved, unless concurrent tentative and final plat submittal has been approved by the PDSD prior to submittal. Final plats may also be submitted for review prior to the approval of a tentative if a minimum of one review of the tentative plat have occurred. In any case, submittal of the final plat prior to approval of the tentative plat is done at the applicant’s risk since changes could be required of the tentative that may affect the final plat. 2-07.4.0 FORMAT REQUIREMENTS Plats must: 4.1 Be on a 24-inch by 36-inch sheet(s) folded to the eight and one-half inch by 11-inch format shown in Exhibit I. The plat may comprise several sheets showing various elements of required data; 4.2 Be prepared on materials that can be transferred to double-matt Mylar reverse read; 4.3 Have a two-inch margin on the left side and one-half inch margins on the remaining sides to comply with standardization requirements of state law for recorded plats; 4.4 Be drawn to a scale of no more than one inch equals 40 feet; and, 4.5 All lettering and dimensions shall be three-thirty-seconds inch in height. 2-07.5.0 CONTENT REQUIREMENTS 5.1 General 2-07.5.1.A A project-location map must be drawn in the upper right corner of the first sheet of the plat at a scale of three inches equals one mile and include the following information: 2-07.5.1.A.3 Subdivisions, arterial and collector streets, major watercourses, and railroads within the one-mile area; and, 1. COMMENT: Ensure that all subdivisions to be label on the location map as noted by the standard above. 2-07.5.1.E Provide a title block in the lower right corner of each sheet with the following information: 2-07.5.1.E.1 Subdivision name; number of blocks, lots, and/or units; and common area; 2. COMMENT: Provide the information noted by the standard above for the Subdivision name and number of block, lots, It is best practice that the title is to be located on the lower right corner as noted by the standard above. 2-07.5.1.H - The Subdivision Case number assigned to the final plat and the DP case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block. If the property is subject to a rezoning case, the C9-__-__ rezoning case number is to be noted also. 3. COMMENT: Provide the information noted by the standard above for the tentative plat. 2-07.5.2 General Notes The plat must include the following general notes. Additional notes specific to each project are required when pertinent. Fill in the blanks with the project-specific information. 2-07.5.2.J If applicable, add the following note: “This subdivision is subject to Ordinance No. ____ which established zoning in the _____________________ Annexation Area.” 4. COMMENT: Provide the information noted by the standard above 2-07.5.3 Standard Paragraphs The plat must include the following statements, as applicable. All signatures must be in permanent, black, India ink and be accompanied by a notary signature and seal. 2-07.5.3.D Approval and Recording Data Blocks The APPROVAL paragraph, where the City Clerk certifies that the plat has been approved by Mayor and Council, and the RECORDING DATA paragraph, which provides space for the recording information, must be placed on the first sheet of the plat adjacent to each other. The paragraphs are as follows. APPROVAL “I, (fill in name of current City Clerk), Clerk of the City of Tucson, Arizona, hereby certify that this plat was approved by the Mayor and Council of the City of Tucson, Arizona, on this ____ day of __________, 20__.” ____________________________________________ ______________ Clerk, City of Tucson Date Sequence________________ Fee_____________________ State of Arizona County of Pima I hereby certify that the instrument was filed for record at the request Of__________________________ Date________________________ Time_________________________ Witness my hand and Official Seal day and year above written. Gabriella Cázares-Kelly, County Recorder BY___________________________ Deputy 5. COMMENT: Relocate the approval block, insure it is presented all in one box as noted by the standard above 2-07.5.3.E Assurances The following ASSURANCE block must be placed on the plat’s first sheet. COMMENT: revise the City engineer to state “City of Tucson Engineer” ASSURANCES “This is to certify that all improvements, such as streets, sidewalks, sewers, water and utility installation, drainage and flood control facilities, and monuments, required by the City of Tucson have been completed or the future completion of such improvements has been assured by a land trust financial assurance agreement, the posting of performance bonds, an escrow account, letter of credit, or other security as the City of Tucson deems necessary and proper. In the event that any such assurance expires, lapses or is otherwise inadequate to assure the completion of assurable infrastructure, the city may suspend the issuance of building permits or certificates of occupancy.” City of Tucson Planning and Development Services Department Director City of Tucson Engineer 2-07.5.4 Proposed Subdivision Information Provide the following information on the plat: 2-07.5.4.H. Show no-vehicular access easements where applicable; 6. COMMENT: If applicable provide the information noted by the standard above. Additional comment may be forthcoming. If you have any questions about this transmittal, Contact Paul Camarena at (520) 837-4986 or by email Paul.Camarena@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
|||