Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: S22-068
Parcel: 13810027B

Review Status: Requires Resubmit

Review Details: LAND DIVISION/SUBDIVISION v.2

Plan Number - S22-068
Review Name: LAND DIVISION/SUBDIVISION v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
Commercial Plumbing APPROVED
Residential Building APPROVED
Commercial Building NOT REQUIRED
Commercial Structural NOT REQUIRED
CDRC Post Review PENDING ASSIGNMENT
Final Plat Package PENDING ASSIGNMENT
External Reviewers - Pima County Assessor REQUIRES RESUBMIT Office of the Pima County Assessor

240 N STONE AVENUE

Tucson, Arizona 85701

SUZANNE DROUBIE

ASSESSOR

TO: CDRC Office

Subdivision Review

City of Tucson (FAX# 791-5559)

FROM: Jaclyn Fajardo

GIS Cartographer

Pima County Assessor’s Office

DATE: 07/26/23

RE: Assessor’s Review and Comments Regarding:

5849 S 6TH AVE Minor Subdivision 1st Submittal

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

Plat meets Assessor’s Office requirements.

___X___ Plat does not meet Assessor’s Office requirements.

COMMENTS:

· THE TITLE BLOCK MUST BE IN THE LOWER RIGHT HAND CORNER. IT MUST HAVE THE NUMBER OF LOTS OR UNITS OR BLOCKS OR ANY COMBINATION OF THESE. IT MUST HAVE THE COMMON AREAS LISTED, IF THERE ARE ANY. IT MUST HAVE THE SECTION, TOWNSHIP AND RANGE AND IF IT IS A RESUBDIVISION, IT MUST MENTION THE PLAT NAME AND THE MAP AND PLAT.

· THE PERIMETER LINE MUST BE SOLID AND HEAVIEST LINE WEIGHT ON THE PLAT. THE LOT LINES AND COMMON AREA LINES MUST BE SOLID AND THE NEXT HEAVIEST. LINES FOR EROSION SETBACKS, FLOODPLAIN LINES ETC. SHOULD BE THE LIGHTEST LINE WEIGHT AND BE DASHED OR DOT-DASHED.

· ALL HATCHING, STIPPLING, STRIPING ETC., MUST BE REMOVED IN THE FINAL PLAT, UNLESS ANOTHER AGENCY REQUIRES IT. IF SO ALL LETTERING MUST HAVE THE HATCHING, ETC., CUT AWAY SO THEY ARE LEGIBLE.

· ALL ADJACENT SUBDIVISIONS SHOULD BE NAMED, WITH MAP AND PLAT IN THE APPROPRIATE AREAS AROUND THE SUBDIVISION.

· CHECK OWNERSHIP TO MAKE SURE IT MATCHES WHAT WE HAVE.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
External Reviewers - Tucson Airport Authority REQUIRES RESUBMIT July 12, 2023
Planning and Development Services
City of Tucson
201 North Stone Avenue
Tucson, AZ. 85701
RE: S22-068, Minor Subdivision / 5849 S. 6th Ave, Tucson, AZ. 85706, Received June 23, 2023
To whom this may concern,
Thank you for the opportunity to comment on S22-068, the minor subdivision plan for three new
lots to support existing and future residential uses at 5849 S 6th Ave. This development is
located in the N.W. quarter of the N.E. quarter of Section 12, Township 15S, Range 13E, of the
Gila and Salt River Meridian. The development site occupies parcel number 138-10-027A and
138-10-027B, covers approximately 2.17 ± acres, and is zoned as Residence Zone 2 (R-2). The
nearest major roadway intersection is East Delta Road and South 6
th Avenue, approximately
200 feet to the southwest of the subject development.
This site does lie within the Tucson International Airport avigation easement requirements and
public disclosure area, FAA traffic pattern airspace, FAA Part 77 airspace, City of Tucson
Airport Environs Overlay Zone – Height Overlay Zone, City of Tucson Airport Environs Overlay
Zone – Hazard District, and the City of Tucson Airport Environs Overlay Zone – Noise Control
District 65
The Tucson Airport Authority objects and does not support the proposed subdivision of the
property since it goes against the Tucson Airport Authority’s adopted Avigation Easement and
Disclosure policy of increasing residential density within the City of Tucson Airport Environs
Overlay Zone – Noise Control District 65. Furthermore, the proposed subdivision is in close
proximity to the primary arrival and departure corridor for all aircraft operating at Tucson
International Airport, which would subject the future residents of this subdivision to regular and
high levels of aircraft noise.
If this proposed subdivision proceeds forward, the Tucson Airport Authority is requiring a
resubmit of this project. These conditions must be included in the plan documents and shall be
identified in the general notes section of all future plans submitted to the City of Tucson for
review.
Conditions of approval:
1. “According to the Federal Aviation Administration (FAA) Notice Criteria Tool, no Notice
Criteria are exceeded. Applicants are therefore not required to file FAA Form 7460.
However, if the use of cranes is anticipated during development and construction
activities, the applicant must file FAA Form 7460 at least 45 days in advance of such
use, to provide the applicant with sufficient time to respond to any concerns identified by
the FAA. Please file Form 7460 at https://oeaaa.faa.gov/oeaaa/external/portal.jsp.”
Although this project does not propose a change in plan designation or zoning the Tucson
Airport Authority highly recommends the applicant add the following notes into the general notes
of the revised development plan. This project is located approximately 0.75 miles northwest of
Tucson International Airport and is within FAA traffic pattern airspace, an area which would be
subject to aircraft overflight and noise due to being in close proximity to Tucson International
Airport.
The proposed notes would provide a means of assuring that future owners and tenants of the
property are aware they are in proximity an airport and further assures the continued right of the
City of Tucson, Tucson Airport Authority, and all persons lawfully utilizing the Tucson
International Airport the right to utilize the airspace above or near the property. This would be
accomplished through the property owner recording the Avigation Easement and providing the
Airport Disclosure Statement to the new residents of all residential uses. The Tucson Airport
Authority believes the proposed note helps to support the City of Tucson Airport Environs
Overlay Zone and supports Plan Tucson – Regional and Global Positioning policy 4 (RG-4).
1. "That prior to the City's approval of the proposed development, the property owner must
record the Avigation Easement that discloses the existence and operational
characteristics of the Tucson International Airport to future owners or tenants of the
property and further conveys the right to the public to lawfully use the airspace above the
property. The Avigation Easement shall be recorded in a manner with the Pima County
recorder which shall document it as having title liability. The content of such documents
shall be according to the form and instructions provided.”
The current property owner or person authorized to sign on behalf of the current property
owner must complete, sign, and record the Avigation Easement. Please record the
Avigation Easement with the Pima County Recorder’s Office. Then send a complete
copy of the recorded easement document to Tucson Airport Authority by either email
(send to srobidoux@flytucson.com) or to the mailing address provided below.
Scott Robidoux
Manager of Planning
Tucson Airport Authority
7250 South Tucson Blvd, Suite 300
Tucson, AZ 85756”
2. Applicable to residential uses only
“The property owner/developer/applicant must provide the Airport Disclosure Statement
form, at time of sale, to the new property owners with all new unit purchases. In the
event the development of any residential uses does not involve the sale of new units but
is instead offering rental residential units to the public, the new tenant of the rental unit
must be provided a copy of the Airport Disclosure Statement form. The intent of the
Airport Disclosure Statement form is to educate and notify the new residents that they
are living near an airport. The content of such documents shall be according to the form
and instructions provided.”
The property owner (for itself or its tenants) shall forward a signed copy of the Airport
Disclosure Statement form to the Tucson Airport Authority within ten (10) days of
signature, using the Scott Robidoux mailing address provided above.
Please do not hesitate to contact me if you have any questions or concerns regarding this
comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-
573-4811.
Respectfully,
Scott Robidoux, C.M.
Manager of Planning

See attachments for TAA's comment letter, Easement and disclosure documents.
External Reviewers - Tucson Electric Power (TEP) REQUIRES RESUBMIT WR#T81391 Monday, August 21, 2023
City of Tucson
Planning and Development Services
Attn: CDRC Admin Team
Dear CDRC Admin Team :
SUBJECT: Emery Park – Lot 21 Lot Split
SS22-068
Tucson Electric Power Company (TEP) has reviewed the development plan submitted
June 23rd 2023. TEP is unable to approve the plan at this time. There are existing
facilities within the development which are not depicted upon the plans, further there are
apparent conflicts. The development plan is not clear on what structures will be
removed, or what new structures will be placed. There is a TEP pole and overhead
conductors within the project. Will need more detailed plans when customer is ready to
proceed in order for TEP to design accurately.
Enclosed is a copy of a TEP facility map showing the approximate location of the
existing facilities. All costs associated with the relocation of the facilities in conflict will
be billable to the developer.
Please resubmit a revised blueline to the City of Tucson for TEP’s review. Should you
have any technical questions, please contact the area Designer, Fred Quintero (520)
235-6329 you have any questions.
Sincerely,
Design Admins
Design Admins
T&D Design
Tucson Electric Power
New Services/JOC REQUIRES RESUBMIT S22-068 - Land Division_Subdivison v2 – 5849 S 6TH AV

1. The title block contains just a legal description of the property being subdivided. At a minimum, it must also indicate the name of the new subdivision and the lot numbers for the lots within the subdivision.

2. The lot number labels on the final plat indicated there will be 3 lots, but the linework indicates there will be only two lots. Revise as necessary.

3. No existing or proposed structures, utility lines, or elevation contours should be shown on the final plat.

4. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
NPPO REQUIRES RESUBMIT The NUOS is not a surveyable line as previously requested, it is lacking dimensions as well.
Site Engineering REQUIRES RESUBMIT 1. Title and Title block should state "final plat for..." not "minor subdivision of..." (AM 2-07)
2. Include a notary signature block for the dedication language (AM 2-07)
3. Submit a recent title report confirming all easements as shown on the plat
4. Provide a Sheet Index on the cover page

Scott Haseman
scott.haseman@tucsonaz.gov
Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: 5849 S 6th Ave – R-2
Final Plat (1st Review)
S22-068

TRANSMITTAL DATE: June 28, 2023

DUE DATE: July 23, 2023

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.
2-07.1.0 APPLICABILITY
Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as “plat” or “plats.”
A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder’s Office. The final plat is kept on file and becomes part of the permanent record for the subject site.
2-07.4.0 FORMAT REQUIREMENTS

1. COMMENT: 2-07.4.2 – The submitted plat is very light and may not record correctly.

2-07.5.0 CONTENT REQUIREMENTS

2-07.5.1 General

2. COMMENT: 2-07.5.1.A.2 – Label the section corners on the location map.

3. COMMENT: 2-07.5.1.A.3 –Label all subdivisions within the one-mile area of the location amp.

4. COMMENT: 2-07.5.1.E.1 – Provide the number of lots in the title block.

5. COMMENT: 2-07.5.1.E.3 – As this is a resubdivision of lot 21 Emery Park No. 1 state so in the title block.

6. COMMENT: 2-07.5.1.E.4 – State “FINAL PLAT” in the tittle and title block.

7. COMMENT: 2-07.5.1.H - The subdivision case number, S22-068, assigned to this plat must be placed in the lower right corner of the plat next to the title block on all sheets.

Additional comments:
8. Provide a supplemental plot plan for lots 1 & 2 that meets the requirements for a residential plot plan found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. A plot plan is not required for Lot 3.

If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov.
CDRC Application Completeness REVIEW COMPLETED
CDRC Review Coordinator REVIEW COMPLETED Added external reviewers, sent emails and sent FYI emails per SOP.
External Reviewers - Pima Association of Governments REVIEW COMPLETED Sent FYI emails per SOP.
External Reviewers - Southwest Gas REVIEW COMPLETED Sent FYI emails per SOP.
External Reviewers - United States Postal Service (USPS) REVIEW COMPLETED Sent FYI emails per SOP.
Fire New Construction REVIEW COMPLETED
OK to Submit - Engineering REVIEW COMPLETED
OK to Submit - Zoning REVIEW COMPLETED