Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/LOT SPLIT v.1
Plan Number - S22-058
Review Name: LAND DIVISION/LOT SPLIT v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
TW Hydraulic Modeling Review | APPROVED | email from: Ray Munoz To: CDRC Sept. 19, 2022 Tucson Water approves this lot split. Parcel A to the south will require a main extension. Thank you, Ray Munoz City of Tucson Tucson Water |
|||
CDRC Post Review | PENDING ASSIGNMENT | ||||
Commercial Plumbing | REQUIRES RESUBMIT | 1. Show how access to the public sewer will be provided for parcel A. Reference: Section 701.3, IPC 2018. 2. Show how parcel A will be provided with water. Reference: Section 107.2.1, IBC 2018 |
|||
Residential Building | REQUIRES RESUBMIT | Show the shed structure with one-hour fire-resistive wall construction parallel with the neighboring property line in compliance with IBC Table 721.1(2) or provide a clear 3’ fire separation distance between the property line and the structure. | |||
Site Engineering | REQUIRES RESUBMIT | 1. The legal description for Parcel B calls out the commencing point as a 1" open pipe, no tag - but the record of survey shows that 1" open pipe with tag LS 4253. Revise as needed for consistency. 2. The last call on the legal description for Parcel B goes SE instead of NW back to the point of beginning. Revise as needed. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
|||
Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: 834 E 9th St S22-058 Land Split (1st Review) TRANSMITTAL DATE: September 20, 2022 SECTION 2-08.0.0: LAND SPLIT 2-08.5.0 CONTENT REQUIREMENTS 1. COMMENT: 2-08.5.B – Parcel A legal description the first bearing lists N 00 36’15” E but the plan shows N00 3615” W. 2. COMMENT: 2-08.5.G – Parcel A does not meet the minimum lot size, 5,000 sq. ft, for an R-3 zoned parcel, see UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES. The legal description will need to combine parcel A with the parcel at 135 N Tyndall. Also, per UDC Article 6.6.2. an accessory building is only allowed on a lot occupied by a principal building or use, Parcel A must be combined with the 135 N Tyndall. 3. Provide a lot coverage calculation that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, for both the proposed Parcel B and combined Parcel A and 135 N Tyndall If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov. |