Plan Number: S22-058
Parcel: 124070780

Address:
834 E 9TH ST

Review Status: Requires Resubmit

Review Details: LAND DIVISION/LOT SPLIT v.1

Plan Number - S22-058
Review Name: LAND DIVISION/LOT SPLIT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
TW Hydraulic Modeling Review APPROVED email from: Ray Munoz
To: CDRC
Sept. 19, 2022

Tucson Water approves this lot split. Parcel A to the south will require a main extension.

Thank you,
Ray Munoz
City of Tucson
Tucson Water
CDRC Post Review PENDING ASSIGNMENT
Commercial Plumbing REQUIRES RESUBMIT 1. Show how access to the public sewer will be provided for parcel A. Reference: Section 701.3, IPC 2018.
2. Show how parcel A will be provided with water. Reference: Section 107.2.1, IBC 2018
Residential Building REQUIRES RESUBMIT Show the shed structure with one-hour fire-resistive wall construction parallel with the neighboring property line in compliance with IBC Table 721.1(2) or provide a clear 3’ fire separation distance between the property line and the structure.
Site Engineering REQUIRES RESUBMIT 1. The legal description for Parcel B calls out the commencing point as a 1" open pipe, no tag - but the record of survey shows that 1" open pipe with tag LS 4253. Revise as needed for consistency.
2. The last call on the legal description for Parcel B goes SE instead of NW back to the point of beginning. Revise as needed.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: 834 E 9th St
S22-058
Land Split (1st Review)

TRANSMITTAL DATE: September 20, 2022

SECTION 2-08.0.0: LAND SPLIT

2-08.5.0 CONTENT REQUIREMENTS
1. COMMENT: 2-08.5.B – Parcel A legal description the first bearing lists N 00 36’15” E but the plan shows N00 3615” W.

2. COMMENT: 2-08.5.G – Parcel A does not meet the minimum lot size, 5,000 sq. ft, for an R-3 zoned parcel, see UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES. The legal description will need to combine parcel A with the parcel at 135 N Tyndall. Also, per UDC Article 6.6.2. an accessory building is only allowed on a lot occupied by a principal building or use, Parcel A must be combined with the 135 N Tyndall.

3. Provide a lot coverage calculation that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, for both the proposed Parcel B and combined Parcel A and 135 N Tyndall
If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov.