Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S21-066
Parcel: 118041300

Review Status: Requires Resubmit

Review Details: LAND DIVISION/SUBDIVISION v.1

Plan Number - S21-066
Review Name: LAND DIVISION/SUBDIVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
External Reviewers - COT Parks & Recreation APPROVED 12/07/2021 COT NON-DSD PARKS & RECREATION Approved Email from: Howard Dutt
To: CDRC
Tue 12/7/2021 1:50 PM

No existing or proposed Tucson Parks and Recreation facilities are affected by this Minor Subdivision.

Howard B. Dutt, RLA
Landscape Architect
Tucson Parks and Recreation
(520) 631-2030
External Reviewers - Tucson Electric Power (TEP) APPROVED
Fire New Construction APPROVED
Site Landscape APPROVED
CDRC Post Review Express PENDING ASSIGNMENT
Final Plat Package Fast PENDING ASSIGNMENT
External Reviewers - Pima County Addressing REQUIRES RESUBMIT 12/08/2021 KAY MARKS PIMA COUNTY ADDRESSING Reqs Change (The ATTACHED PDF mentioned below can be viewed in the "Documents" section of PRO: "Pima Co Addressing, review comments, first submittal")

Email from: <Addressing@pima.gov>
To: CDRC
Tue 12/7/2021 1:46 PM

San Jose, S21-066, 1st submittal review is being Returned for Corrections by Pima County Addressing.
The attached pdf contains Addressing’s comments.
Please let me know if you have any questions or if I may assist further.

Thank you,
Robin Freiman, Addressing Official

Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-7570
External Reviewers - Pima County Assessor REQUIRES RESUBMIT 11/17/2021 ED ABRIGO PIMA COUNTY ASSESSOR Reqs Change (This letter can be viewed in the "Documents" section of PRO: "Pima Co Assessors, review comments, first submittal, 11.16.21")

FROM: Ada Janson, GIS Cartographer, Pima County Assessor’s Office

DATE: November 16, 2021

RE: Assessor’s Review and Comments Regarding:
S21-066 1ST SUBMITTAL SAN JOSE LOTS 1 - 3

___X___ Plat does not meet Assessor’s Office requirements.

COMMENTS:

1. THE TITLE BLOCK IN THE LOWER RIGHTHAND CORNER DOES NOT LIST A SUBDIVISION NAME, NUMBER OF LOTS OR UNITS OR BLOCKS OR ANY COMBINATION OF THESE. IF IT IS A RESUBDIVISION, IT MUST STATE THAT IT IS A RESUBDIVISION WITH THE PLAT NAME AND THE MAP AND PLAT.

2. THE LOCATION MAP MUST BE IN THE UPPER RIGHT HAND CORNER AND MUST HAVE THE SECTION, TOWNSHIP AND RANGE. THE PROJECT AREA SHOULD BE OUTLINED OR HAVE AN ARROW POINT TO IT.

3. GENERAL NOTES MUST HAVE THE TOTAL NUMBER OF LOTS (IT LISTS “2”, BUT 3
LOTS ILLISTRATED).

4. THERE MUST BE A SECTION TIE, WITH A BEARING AND DIMENSION FROM THE
SECTION CORNER OR QUARTER CORNER TO THE POINT OF TIE ON THE SUBDIVISION.

5. ALL ADJACENT SUBDIVISIONS SHOULD BE NAMED, WITH MAP AND PLAT IN THE APPROPRIATE AREAS AROUND THE WHOLE SUBDIVISION. (MISSING WEST, EAST & SOUTH SIDES)

6. OWNERSHIP DOES NOT MATCH OUR RECORDS. OUR RECORDS INDICATE: SALAZAR INVESTMENTS PSP LLC, AS THE CURRENT OWNER.
External Reviewers - Pima County Wastewater (RWRD) REQUIRES RESUBMIT 11/09/2021 PIMA COUNTY WASTEWATER Reqs Change To: Applicant
From: Planning & Development Services Dept.

Contact Pima County Wastewater at email: Sewer@Pima.gov or phone (520) 724-6500 to request their approval for wastewater. Submit the approval letter to the City of Tucson with your next submittal.
New Services/JOC REQUIRES RESUBMIT 11/09/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Reqs Change To: Applicant
From: Planning & Development Services Dept.

Contact Tucson Water to request a Water Availability letter. Include the Letter in your next submittal. This is required before the last step of Mayor and Council's approval of the Minor Subdivision.
Site Engineering REQUIRES RESUBMIT 02/02/2022 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. Provide the correct basis of bearing in the general notes, or remove the b-o-b note from the general notes.
2. Provide the correct name for the City Clerk. Mr. Randolph has retired. The new City Clerk is Suzanne Mesech.

Loren Makus
loren.makus@tucsonaz.gov
Site Zoning REQUIRES RESUBMIT 12/06/2021 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: 1691 S San Jose Dr – Lots 1-3
FINAL PLAT (1st Review)
S21-066

TRANSMITTAL DATE: December 6, 2021

DUE DATE: December 8, 2021

2-07.1.0 APPLICABILITY
Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as “plat” or “plats.”
A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder’s Office. The final plat is kept on file and becomes part of the permanent record for the subject site.
2-07.5.0 CONTENT REQUIREMENTS
2-07.5.1 General
1. Comment: 2-07.5.1.A - A project-location map must be drawn in the upper right corner of the first sheet of the plat at a scale of three inches equals one mile and include the following information:
2. Comment: 2-07.5.1.A.1. The project site approximately centered within a one square mile area;
3. Comment: 2-07.5.1.A.2. Label the section, township, and range; section corners; north arrow; and the scale;
4. Comment: 2-07.5.1.A.3. Subdivisions, arterial and collector streets, major watercourses, and railroads within the one-mile area; and,
5. Comment: 2-07.5.1.A.4. The city’s jurisdictional limits, if within the mapped area.

6. Comment: 2-07.5.1.E. Provide a title block in the lower right corner of each sheet with the following information:
7. Comment: 2-07.5.1.E.1- Subdivision name and the number of lots.
8. Comment: 2-07.5.1.E.3 - If the final plat is a resubdivision of a previously recorded plat, indicate the title and the book and page/sequence number reference of the existing subdivision; and
9. Comment: 2-07.5.1.E.4. State “FINAL PLAT” in the tittle and title block.

10. Comment: 2-07.5.1.H – Provide the subdivision case number, S21-066, in the lower right corner of the plat next to the title block on all sheets.

The plat must include the following general notes. Additional notes specific to each project are required when pertinent. Fill in the blanks with the project-specific information.
11. Comment: 2-07.5.2.B – General Note 2 states “NUMBER OF LOTS IS 2” but you show 3.
2-07.5.3 Standard Paragraphs
The plat must include the following statements, as applicable. All signatures must be in permanent, black, India ink and be accompanied by a notary signature and seal.
12. Comment: 2-07.5.3.D – Remove the Clerks name from the signature line of the approval block.

13. Comment: 2-07.5.3.D – The approval block shall match what is shown in AM 2-07.
2-07.5.4 Proposed Subdivision Information
Provide the following information on the plat:
14. 2-07.5.4.E – Remove the perimeter yard setback lines and dimensions from the plat as they are not correct and are not required.
If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov.
RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Final Plat
Traffic Engineering Review REQUIRES RESUBMIT 12/08/2021 COT NON-DSD TRAFFIC Reqs Change Email from: David.Stiffey@tucsonAz.gov
To: CDRC
Wed 12/8/2021 11:21 AM

1. Please provide information and details regarding new:
a. Curb
b. Sidewalk
c. Curb Access Ramp
Along San Jose Dr.

2. Show sidewalk along the frontage of San Luis Blvd.


David Stiffey
City of Tucson
Commercial Plumbing REVIEW COMPLETED
External Reviewers - Pima Association of Governments REVIEW COMPLETED
External Reviewers - Southwest Gas REVIEW COMPLETED
External Reviewers - United States Postal Service (USPS) REVIEW COMPLETED