Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/SUBDIVISION v.3
Plan Number - S21-066
Review Name: LAND DIVISION/SUBDIVISION v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| External Reviewers - Pima County Addressing | APPROVED | [EXTERNAL] Approval S21-066 Nicholas Jordan CDRC management@graceconstructionaz.com Good morning, Pima County Addressing approves S21-066. Thank you Nicholas Jordan Site Review Project Manager – Addressing Official Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-9623 |
|||
| CDRC Post Review Express | PENDING ASSIGNMENT | ||||
| Final Plat Package Fast | PENDING ASSIGNMENT | ||||
| New Services/JOC | REQUIRES RESUBMIT | S21-066 - Land Division_Subdivison v3 – 1691 S SAN JOSE DR 1. A thin line, broken with the letters, “HW” was shown crossing the west ends of proposed Lots 1-3, and just outside the east ends of proposed Lots 1-3 The Legend does not contain an example of this line and explain what this line represents. All line-types used on the proposed plat must be shown in the legend and/or labeled, so that their meaning is clear to the reader. 2. Generally speaking, a final plat should show only lines that represent some form of the property line or boundaries, such as the subdivision boundary, the lot lines, and easement lines. Lines representing most physical features, such as proposed or existing walls, water lines, sewer lines, etc., should not be shown on final plats. These should be shown only on a separate plot plan. Please remove the proposed sewer lines and most other lines representing physical features from the final plat. 3. The Legend on a final plat should show only those symbols used on the final plat. Delete the symbols for Clean-Outs, Fire Hydrants, Gas Meters, and other unused symbols from the Legend. 4. The Legend should show and explain all symbols used on the final plat. The black 5 sided star on Lot 1 was not shown or explained in the legend. Revise as necessary. 5. The infrastructure in the streets does not need to be shown on the final plat. The centerlines of the streets do need to be shown on the final plat, along with the half right of way widths, and the full right of way widths, the street names, and whether they are public or private. 6. The Basis of Bearing has been shown in General Note 7 and in a separate Basis of Bearing block near the Certification of Survey. It should be shown only in the separate Basis of Bearing block near the Certification of Survey. 7. Delete the label on Lot 3 that reads, “Lot 6, Block 1, Parcel ID: 118041300”. 8. Delete the label on Lot 2 that reads, “Parcel ID: 118041300, Owner: Salazar Investments PSP LLC, Owner Address : 3900 N. Stone Ave, Tucson AZ 85705-3208” 9. Under the Dedication statement: Show the full name of the owner and the owner’s address. 10. A final plat is not a permit. Delete “Permit #” where it appears just above the Sheet number. Leave “S21-066”. 11. The .pdf file named S21-066 Response_v1.pdf submitted on 08/01/2023 could not be opened and was not considered in this review. 12. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
|||
| Site Engineering | REQUIRES RESUBMIT | The City Clerk's name is spelled Suzanne Mesich. Please revise. Lianne Evans lianne.evans@tucsonaz.gov |
|||
| Site Zoning | REQUIRES RESUBMIT | CDRC TRANSMITTAL FROM: PDSD Zoning Review PROJECT: 1691 S San Jose Dr – Lots 1-3 FINAL PLAT (2nd Review) S21-066 TRANSMITTAL DATE: July 17, 2023 DUE DATE: August 11, 2023 2-07.1.0 APPLICABILITY Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as “plat” or “plats.” A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder’s Office. The final plat is kept on file and becomes part of the permanent record for the subject site. 2-07.5.0 CONTENT REQUIREMENTS 2-07.5.1 General 1. This comment was not correctly addressed. The location map shows the scale at “N.T.S.” Comment: 2-07.5.1.A - A project-location map must be drawn in the upper right corner of the first sheet of the plat at a scale of three inches equals one mile and include the following information: 2. This comment was not fully addressed. The section corners are not labeled on the location map. Comment: 2-07.5.1.A.2. Label the section, township, and range; section corners; north arrow; and the scale; 3. This comment was not fully addressed. The subdivisions have not been labeled on the location map. Comment: 2-07.5.1.A.3. Subdivisions, arterial and collector streets, major watercourses, and railroads within the one-mile area; and, If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Final Plat |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED |