Permit Number: DP22-0164
Parcel: 14041127E

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE REVIEW v.2

Permit Number - DP22-0164
Review Name: DEVELOPMENT PACKAGE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/01/2023 Commercial Plumbing APPROVED
03/08/2023 Site Engineering APPROVED
02/16/2023 Site Landscape APPROVED
03/08/2023 CDRC Post Review Express PENDING ASSIGNMENT
02/16/2023 External Reviewers - COT Environmental Services REQUIRES RESUBMIT RE: PDSD review request of resubmittal for permit DP22-0164

Andy Vera
CDRC
Pat Tapia
ES Comments Are as follows:

Must include provisions for both trash and recycle storage and collection. Refer to TSM 8-01.1.0. Current drawing proposes one single enclosure at the NE and SW corners of the building/development. Either add another single enclosure next to the current proposed or two double container enclosures. Refer to TSM 8-01.9.0, figure 3A or 3B.
No enclosure detail provided. Include detail drawings of enclosure/s with dimensions. TSM 8-01.4.A & 8-01.5.2
Depict 14’x40’ approach in front of enclosure. TSM 8-01.5.3.B
Fell free to contact me with any questions or comments regarding this review.

Thanks,
Andy Vera
City of Tucson -Environmental Services
Accounts Representative Supervisor
(520) 837-3798
02/23/2023 Fire New Construction REQUIRES RESUBMIT Section D105.3 Proximity to building. One or more of required access routes meeting this condition shall be located not less than 15 feet (4572 mm) and not greater than 30 feet (9144 mm) from the building and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approve by the fire code official.

Questions:

Jennifer Peel-Davis
Tucson Fire Department
Fire Plans Examiner
Fire Inspector I, II and Fire Alarm Plans Examiner
Jennifer.Peel-Davis@Tucsonaz.gov
Desk: 520-837-7033
02/28/2023 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Alvernon Way Distribution Center – Building 1
Development Package (3rd Review)
DP22-0164

TRANSMITTAL DATE: February 28, 2023

DUE DATE: March 4, 2023

COMMENTS: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is June 16, 2023.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

1. This comment was not addressed. The bicycle parking calculation is not correct. Per UDC Article 7.4.3.G Fractional Amounts, when the calculation of required motor vehicle, bicycle parking spaces, and EVSE spaces results in a fractional number, a fraction of one-half or more is adjusted to the next higher whole number, and a fraction of less than one-half is adjusted to the next lower whole number. Based on the square footage of 173,031/40,000 the required number should be 4. The calculation shall show the number required & provided and a detail will be provided on the plan that clearly demonstrates that the requirements of UDC Article 7.4.9 are met. The long-term bicycle parking shown on the plan appears to be bike racks. Bike racks do not meet the requirements of UDC Article 7.4.9.D. COMMENT: 2-06.4.9.H.5.d – Provide a Short- & Long-term bicycle parking space calculation on the plan the provides the number required and provided.

2. COMMENT: 2-06.4.9.Q – The square footage shown within the footprint does not match the square footage used in the vehicle & bicycle parking calculations.

3. Based on you response “The existing eastern most access lane has flush curb” demonstrate on the plan how the requirements of TSM Section 7-01.4.2 are met COMMENT: 2-06.4.9.R – As this parcel has street frontage along Alvernon Way provide the required sidewalk from the proposed building to the right-of-way line along Alvernon, see TSM Section 7-01.4.1.A.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov.
02/16/2023 CDRC Review Coordinator Express REVIEW COMPLETED