Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE REVIEW v.1
Permit Number - DP22-0109
Review Name: DEVELOPMENT PACKAGE REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/24/2023 | CDRC Post Review | PENDING ASSIGNMENT | |||
03/24/2023 | Site Engineering | REQUIRES RESUBMIT | 1. Ensure 4' pedestrian path maintained with a 2.5' overhang, esp. at the handicapped spaces 2. Provide more grading detail on the proposed rear water harvesting, showing how it will drain into the trench drain per keynote 5 Scott Haseman scott.haseman@tucsonaz.gov |
||
03/23/2023 | Site Zoning | REQUIRES RESUBMIT | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Paul Camarena PDSD Zoning Review Section PROJECT: 3470 S KINO PW Development Package (2nd Review) DP22-0109 TRANSMITTAL DATE: March 23, 2023 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is May 5 , 2023. COMMENT: Update the tracking table to reflect the actually square footage, revise page 5 to show the correct square footage. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. If the property is being rezoned, use those boundaries and classifications. The basis for this requirement is that some zoning requirements on a project are based on the zoning classification of adjacent property. Also, in some instances, each zone has to be taken into consideration on property that is split by two or more zoning classifications, as each may have different requirements. This comment is still applicable provide the zoning classification on the site. COMMENT: 2-06.4.9.F - Provide the information noted by the standard above for the property across Kino 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s). This comment is still applicable provide the use within the building footprint. COMMENT: 2-06.4.9.Q -Provide the information noted by the standard above to show the proposed uses within the footprint of the building. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. This comment is still applicable provide lot 8. Per TSM Section 7. “All sidewalks must be a minimum of four feet wide and installed to avoid any obstruction which decreases the minimum width to less than four feet.” The side walk along the Accessible parking spaces will overhang into the 4ft sidewalk reducing the width to 3.5’. COMMENT: 2-06.4.9.R - Provide the information noted by the standard above, show pedestrian circulation to lot 8. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, Contact Paul Camarena aat (520) 837-4986 or by email Paul.camarena@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
||
03/22/2023 | CDRC Application Completeness | REVIEW COMPLETED |