Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: DP21-0156
Parcel: 106031180

Address:
266 W NAVAJO RD

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE REVIEW v.1

Permit Number - DP21-0156
Review Name: DEVELOPMENT PACKAGE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/06/2023 External Reviewers - Tucson Electric Power (TEP) APPROVED Email from: TEP-DEVREV <TEPDEVREV@tep.com>
To: CDRC
Thu 5/12/2022 11:35 AM

Tucson Electric Power Co., (TEP) has reviewed and has no objection to Lot 22 of Sawtelle Place, Tentative Plat, DP21-0156.

Subdivision, submitted on 2022. There are existing TEP facilities within the boundaries of the plat. Costs for removing or relocating existing TEP facilities will be billable to the developer.

Please call the New Construction Department at 520-918-8300 to apply for service for new development. Submit a final set of approved plans, including electrical load and offsite improvement plans to determine how TEP will serve this development. If easements are required for new TEP facilities, they will be obtained by separate instrument.

If there are any questions, don't hesitate to contact Land Resources at tepdevrev@tep.com.

Tucson Electric Power Co.
Land Resources Department
03/06/2023 CDRC Post Review PENDING ASSIGNMENT
03/06/2023 Commercial Plumbing REQUIRES RESUBMIT 1. A separate permit is required for the installation of a private sewer collection system and will require a review of the system design by the Pima County Department of Environmental Quality. Reference Title 18, R18-9-E302, 4.02 General Permit, Arizona Administrative Code.
2. The new 8" private sewer is shown connecting to an existing 6" public sewer. Provide documentation from Pima county that shows that this will be allowed. Reference: Section 107.2.1, IBC 2018.
3. Explain the 5" water line. How is it connecting to the municipal water service system? How will the five lots be provided with water? Reference: Section 107.2.1, IBC 2018.
03/06/2023 Fire New Construction REQUIRES RESUBMIT Plans shall show the existing fire hydrants to determine if new fire hydrants are required

If you have any fire questions please contact me:

Jennifer Peel-Davis
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
Fire Plans Examiner
03/06/2023 NPPO REQUIRES RESUBMIT
03/06/2023 ROW Engineering Review REQUIRES RESUBMIT DP21-0156
Comments:
1. Where 20' driveway ties-in to Navajo Rd. a P.A.G. standard 206 driveway apron is needed.
2. New 5' wide sidewalk per P.A.G. standard 200, along the entire property frontage.
3. Concrete Header per P.A.G. standard 213, where new 20' driveway meets the alley at the north of the project.
4. Concrete curb in the Right of Way, per P.A.G. standard 209.
5. Concrete Curb Terminal per P.A.G. standard 212 at east and west end of property where new concrete curb ends.
6. 3' minimum buffer between new concrete curb on Navajo and the new 5' wide sidewalk.

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
03/06/2023 Site Engineering REQUIRES RESUBMIT 1. Revise the drainage statement to use the hydraulic cross-sections to determine base flood elevations for the site.
2. Complete the information on page 6 of the report.
3. Provide an encroachment analysis to demonstrate no adverse impact with the construction of the proposed structures.
4. Provide the information and exhibits as indicated by the section title pages.
5. Show the basis of bearing on the plans and tie it to the property corners.
6. The easement provides access to more than 3 residential unit and must be developed as a street. Show full street profile with parking and sidewalks.
7. Show how guest parking will be provided.
8. Show vehicle use areas and parking on individual lots.
9. Show how setback from Navajo Road will be met.
10. Show conditions on adjacent properties including buildings. Address how buildings on adjacent properties affect hydraulics.
11. Show how solid waste containers will be stored and serviced.

Loren Makus
loren.makus@tucsonaz.gov
03/06/2023 Site Landscape REQUIRES RESUBMIT A Native Plant Preservation Plan is required with this submittal.
03/06/2023 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Lot 22 of Sawtelle Place – Tentative Plat
Development Package (1st Review)
DP21-0156

TRANSMITTAL DATE: May 11, 2022

DUE DATE: May 11, 2022

COMMENTS: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is May 03, 2023.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.2.B – As this is a resub of Lot 22 of Sawtelle Place state that this is a ‘RESUBDIVISION OF LOT 22 SAWTELL PLACE” within the title block.

2. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0156, adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

3. COMMENT: 2-06.4.7.A.2 – Under General Note 1 you list the square footage of the existing parcel as “29,741 SF”. On the plan you list each lot as having “5,950 Sf”. 29,741/5 = 5948.2 SF for each lot. Clarify which square footage is correct.

4. COMMENT: 2-06.4.7.A.4 – Based on information provided on the plan you are proposing a duplex on each lot. If this is the case the use listed under General Note 26 is not correct and should be listed as “DUPLEX SUBJECT TO USE SPECIFIC STANDARDS 4.9.7.B.6, .9, & .10”

5. COMMENT: 2-06.4.7.A.4 – Revise General Note 26 to include the existing use.

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

6. COMMENT: 2-06.4.8.C – Provide the following information for Navajo Rd: dimensioned width of paving.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

7. COMMENT: 2-06.4.9.B – Provide the lot number for each lot on the plan.

8. COMMENT: 2-06.4.9.F – Provide the existing zoning classifications for the parcels north of the alley and south of Navajo Rd on the plan with zoning boundaries clearly defined.

9. COMMENT: 2-06.4.9.H.5 – Until comment ## is addressed Zoning cannot determine the width requirements for the proposed driveway called out under Keynote 1.

10. COMMENT: 2-06.4.9.H.5.a – Show the required vehicle parking on the plan.

11. COMMENT: 2-06.4.9.H.5.a – Under the “PARKING CALCULAITON” you list “MULTI FAMILY DWELLING UNIT”. It does not appear that this is correct. Based on 5 individual lots with only a duplex on each lot, this is not considered multi-family.

12. COMMENT: 2-06.4.9.H.5.d - Based on 5 individual lots with only a duplex on each lot, bicycle parking is not required.

13. COMMENT: 2-06.4.9.L – Show the proposed “PRIVATE INGRESS EGRESS/ UTILITY EASEMENT” to be per final plat.

14. COMMENT: 2-06.4.9.O – Revise the setbacks list under the General Notes to include the required street perimeter yard setbacks for the southernmost lot, see UDC Article 6.4.5.C.1.a.

15. COMMENT: 2-06.4.9.V – Indicate how each individual lot will receive mail on the plan.

2-06.5.0 FLEXIBLE LOT DEVELOPMENT (FLD - ADDITIONAL REQUIREMENTS)

If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package