Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: DP21-0086
Parcel: 121021910

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE REVIEW v.2

Permit Number - DP21-0086
Review Name: DEVELOPMENT PACKAGE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/26/2024 CDRC Post Review Express PENDING ASSIGNMENT
03/26/2024 CDRC Review Coordinator Express PENDING ASSIGNMENT
03/26/2024 Commercial Plumbing PENDING ASSIGNMENT
03/26/2024 Fire New Construction PENDING ASSIGNMENT
03/26/2024 NPPO PENDING ASSIGNMENT
03/26/2024 ROW Engineering Review PENDING ASSIGNMENT
03/26/2024 Site Engineering PENDING ASSIGNMENT
03/26/2024 Site Landscape PENDING ASSIGNMENT
03/26/2024 Site Zoning PENDING ASSIGNMENT
03/26/2024 OK to Submit - Zoning Fast REQUIRES RESUBMIT FROM: PDSD Zoning Review

PROJECT:
T21CM01130
7266 E. Paseo San Andres - R-1
Porch built w/o permit (7th Review)


TRANSMITTAL: March 26, 2024

Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9

1. The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation.

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

1. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of less than 9’-0” the required perimeter yard setback form the detached shed to the south property line is 6’-0”, proposed setback is 1’-8”.

2. The minimum setback to the front street perimeter property line is twenty (20) feet (UDC 6.4.5.C.1.a). As the post supporting the porch are not shown on the plot plan and a dimension was not provided from the post supporting the porch to the front street property line Zoning will use the provided 11’-7” setback shown on the plot plan. The proposed front street perimeter yard setback is 11’-7”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

3. Until the DDO is approved Zoning cannot approve this plan.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov
03/20/2024 CDRC Application Completeness Express REVIEW COMPLETED
03/26/2024 OK to Submit - Engineering Fast REVIEW COMPLETED
03/21/2024 OK to Submit - Landscape Fast REVIEW COMPLETED