Permit Number: DP20-0173
Parcel: 14042021A

Address:
2830 E MEDINA RD

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE REVIEW v.2

Permit Number - DP20-0173
Review Name: DEVELOPMENT PACKAGE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/15/2023 CDRC Post Review Express PENDING ASSIGNMENT
06/15/2023 CDRC Review Coordinator Express PENDING ASSIGNMENT
06/15/2023 Fire New Construction PENDING ASSIGNMENT
06/15/2023 NPPO PENDING ASSIGNMENT
06/15/2023 Site Engineering PENDING ASSIGNMENT
06/15/2023 Site Landscape PENDING ASSIGNMENT
06/15/2023 Site Zoning PENDING ASSIGNMENT
06/15/2023 OK to Submit - Zoning Fast REQUIRES RESUBMIT CDRC TRANSMITTAL

PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: TAC2 – New Shell Building
Development Package (OK to Submit - Revision #13)
DP20-0173

TRANSMITTAL DATE: June 15, 2023

DUE DATE: June 21, 2023

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

2-06.3.0 FORMAT REQUIREMENTS

1. This comment was not addressed correctly. The accessory use was not added to General Note 3. Return the first part of General Note 3 to the original state, and add “HAZARDOUS MATERIAL STORAGE, SUBJECT TO USE SPECIFIC STANDARDS 4.9.10.B.1 & 2.d” as a separate use. Also per UDC Article 4.9.10.B.1.b.(3) a screen wall, equal to the height of the tank, is required along the west side of the proposed tank. Per UDC Article 4.9.10.B.2.d the tank is limited to 10,000 gallons. A Board of Adjustment for Variance is required for the proposed 12,000 gallon tank. COMMENT: 2-06.4.7.A.4 – Add the proposed accessory use, “HAZARDOUS MATERIAL STORAGE, SUBJECT TO USE SPECIFIC STANDARDS 4.9.10.B.1 & 2.d”, to General Note 3. Clearly demonstrate on the plan that all requirements of UDC Use Specific Standards 4.9.10.B.1 & 2.d are met.

If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
06/14/2023 CDRC Application Completeness Express REVIEW COMPLETED