Permit Number: DP20-0060
Parcel: 11306142J

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE REVIEW v.1

Permit Number - DP20-0060
Review Name: DEVELOPMENT PACKAGE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/04/2023 CDRC Post Review PENDING ASSIGNMENT
05/04/2023 CDRC Review Coordinator PENDING ASSIGNMENT
05/04/2023 Commercial Plumbing PENDING ASSIGNMENT
05/04/2023 Fire New Construction PENDING ASSIGNMENT
05/04/2023 NPPO PENDING ASSIGNMENT
05/04/2023 ROW Engineering Review PENDING ASSIGNMENT
05/04/2023 Site Engineering PENDING ASSIGNMENT
05/04/2023 Site Landscape PENDING ASSIGNMENT
05/04/2023 Site Zoning PENDING ASSIGNMENT
05/03/2023 OK to Submit - Landscape REQUIRES RESUBMIT PROJECT: DUTCH BROS COFFEE – NWC OF FORT LOWELL & CAMPBELL
ACTIVITY NO. DP-20-0060
ADDRESS/PARCEL: 3205 N CAMPBELL AV/113-06-142J
ZONING: C-1

COMMENTS:
1. A Commercial Rainwater Harvesting plan is required per UDC Technical Standards Manual – Section 4-01.3.0. and Section 5-01.0.0 Landscaping and Screening. Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design. Using Low Impact Development design and water harvesting provides critical basin detention and first flush retention for all new development and impervious area. The newly adopted Detention/Retention Manual can be found: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf

With CoT edits to the manual are found at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf


If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988
05/04/2023 OK to Submit - Zoning REQUIRES RESUBMIT CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: Dutch Bros- NWC of Fort Lowell & Campbell
Development Package (2nd Review)
DP20-0060

TRANSMITTAL DATE: May 4, 2023

DUE DATE: May 9, 2023

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is March 17, 2021.


CONTENT REQUIREMENTS

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

1. As you are proposing not to combine the lots and cross access & parking is proposed, a Covenant Regarding Development and Use of Real Property will need to be executed and recorded along with a cross access/parking agreement will need to be recorded prior to approval of this DP. The covenant can be found at: https://www.tucsonaz.gov/files/pdsd/Covenant_Regarding_Development_and_Use_of_Real_Property_UDC.pdf. 2-06.4.9.A – A lot combination will need to be completed prior to approval of the development package.

If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov.
RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
05/02/2023 CDRC Application Completeness REVIEW COMPLETED
05/03/2023 OK to Submit - Engineering REVIEW COMPLETED