Review Status: Requires Resubmit

Review Details: CIP - DEV SITE + COMM STRUCTURE - FINAL v.1

Plan Number - CIP-0925-00024
Review Name: CIP - DEV SITE + COMM STRUCTURE - FINAL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
Site Engineering APPROVED
Site Landscape APPROVED
Traffic Engineering Review APPROVED Traffic Engineering has no further comments.
Neighborhood Traffic Mitigation PENDING ASSIGNMENT
CDRC Post Review Express REQUIRES RESUBMIT Please address reviewers comments and resubmit.
External Reviewers - Tucson Electric Power (TEP) REQUIRES RESUBMIT March 31, 2026
WO#T164426
City of Tucson
Planning and Development Services
Attn: CDRC Admin Team
Dear CDRC Admin Team
Subject: MIRASOL PARK
CIP-0925-00024
Tucson Electric Power Company (TEP) has reviewed and cannot approve the development plan submitted 3/16/2026. There are no existing facilities within the development.NO APPARENT CONFLICTS Further: TEP easements not shown on Development plans. Bk 638 Pg 28, Bk 4188 Pg 542, Bk 4455 Pg 610 & Bk 4632 Pg 633
Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.
To apply for electric service, please call the New Construction department at (520) 918-8300. Please submit a final set of plans including approved site, electric load, paving off-site improvements and irrigation plans. If available, include a PDF version of the plans.
If easements are required, they will be secured by separate instrument. Should you have any easement questions, please contact our Land Resources Department,
LandReviews@tep.com.
Should you have any technical questions, please contact the area designer,
Martin Salazar
(520) 305-6713
msalazar@tep.com
Sincerely,
Design Admins
Design Admins
Tucson Electric Power
Bldg Permits - Post Review Express REVIEW COMPLETED
CDRC Application Completeness Express REVIEW COMPLETED
Commercial Building REVIEW COMPLETED
Commercial Electrical REVIEW COMPLETED No comment.
Commercial Mechanical REVIEW COMPLETED
Commercial Plumbing REVIEW COMPLETED
Fire New Construction REVIEW COMPLETED No comments
Outdoor Lighting REVIEW COMPLETED No comment.
PDSD Application Completeness Express REVIEW COMPLETED
ROW Engineering Review REVIEW COMPLETED Coordinate with DTM Planning for potential cost sharing agreements for ramps and driveway.
Site Zoning REVIEW COMPLETED FROM: Loran Shamis
PDSD Zoning Review Section
PROJECT: CIP-0925-00024
1100 E Silverlake RD
Mirasol Park (2nd Review) (Final Review)
TRANSMITTAL DATE: April 2, 2026

COMMENTS: Resubmit revised drawings along with a detailed response letter explaining how each comment was addressed submitted as a formal Development Package.

1. COMMENT: Include the case number CIP-0925-00024 in the bottom right corner.

2. COMMENT: This comment was not addressed - Comment: In the project-location map identify and label the Railroad, Silverlake RD, Kino PW, and Park AV.

3. COMMENT: This comment was not addressed - Comment: Correct the use specific standards to only include “4.9.13.B & C” under project data. Remove use specific standard 4.9.13.K, as it is not applicable for the existing and proposed use in this zone.

4. COMMENT: This comment was not addressed - Correct the setback information under the site data on page two to comply with Nonresidential uses. Update the Project Data section note to say the Required Street Setback. The minimum required setback to the North, South, and West is 20’ measured from the existing property line and the minimum setback requirement to the East is 10’ measured from the existing or future property line. Include the proposed setbacks in addition to the minimum required setbacks.

5. COMMENT: This comment was not addressed: Include the total lot coverage calculations for the site. Per UDC table 6.3-2.B: Exceptions to the R-2 dimensional standards, Parks and Recreation uses are permitted a maximum 60% lot coverage. Demonstrate compliance with this standard.

6. COMMENT: This comment was not addressed - Comment: Place the C9-56-57 and the plan/plat file numbers in the lower right corner of each sheet.

7. COMMENT: Please include a note adjacent to the parking calculations that states “Reduced parking granted through City Manager Waiver in accordance with Section V of the Administrative Directive 1.07-6. (UDC 5.12.6.M).”

8. COMMENT: This comment was not addressed - Comment: Identify the floor area for each building.

9. COMMENT: This comment was not addressed – Comment: All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. Provide the zoning classification on adjacent properties, including across any adjacent right of way.

10. COMMENT: This comment was not addressed - Comment: Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s).

11. COMMENT: Include a copy of the CMO waiver in the plan set.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Formal Development Package addressing the above comments, and a Comment Response Letter explaining how each comment has been addressed.
If you have any questions about this transmittal, please contact Loran.Shamis@tucsonaz.gov
TW Planning and Engineering Review REVIEW COMPLETED Transferred to Ramiro Olivarez from Michael Asbury CONDITIONALLY APPROVED
Comment: On sheet 7, Keynote 7, ensure a 5 ft horizontal distance from the outside of the LP foundation to the water service line is maintained.
For any questions, please contact Ramiro at Ramiro.Olivarez@tucsonaz.gov
Water - PDSD REVIEW COMPLETED ACTIVITY NO. CIP-0925-00024
ADDRESS/PARCEL: 1100 E Silverlake RD Tucson, AZ 85713

COMMENTS:
1. The RIM elevation of the nearest upstream manhole (#5671-08) is 2455.88 and the FFE of new building is 2456.00. Since the FFE is less than 12 inches above the elevation of the next upstream manhole cover, a backwater valve will be required. Reference: Section 714.1, IPC 2024, as amended by the City of Tucson.