Plan Review Detail
Review Status: Approved
Review Details: CIP - DEV SITE + COMM STRUCTURE - FINAL v.1
Plan Number - CIP-0725-00017
Review Name: CIP - DEV SITE + COMM STRUCTURE - FINAL v.1
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Traffic Engineering Review | APPROVED | Traffic Engineering would suggest all parking stall markings be white | |||
| Neighborhood Traffic Mitigation | NOT REQUIRED | ||||
| Real Estate | NOT REQUIRED | If any action is required to address property rights (dedications, easements, etc), please contact the Real Estate Division 520-791-4181. | |||
| TSMR/PDMR - Engineering | NOT REQUIRED | ||||
| TSMR/PDMR - Environmental Services | NOT REQUIRED | ||||
| Zoning Administration | NOT REQUIRED | ||||
| Zoning Compliance Review | NOT REQUIRED | ||||
| Bldg Permits - Post Review Express | REVIEW COMPLETED | ||||
| Building Official | REVIEW COMPLETED | ||||
| CDRC Application Completeness Express | REVIEW COMPLETED | CDRC added ADOT, TEP, sent out FYIs to SWG, USPS, PAG. | |||
| Commercial Building | REVIEW COMPLETED | Remove the Preliminary Not For Construction annotation over registrant's stamp on Sheet G300 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
|||
| Commercial Electrical | REVIEW COMPLETED | no comments. | |||
| Commercial Mechanical | REVIEW COMPLETED | Ventilation calculations have been provided for the fitness area; provide ventilation calculations for all of the other occupied areas that are part of this activity. Reference: Sections 401.2 and 401.3, IMC 2018.. | |||
| Commercial Plumbing | REVIEW COMPLETED | Provide a cleanout for the existing 4” horizontal drain at the connection of the new waste piping. Reference: Section 708.1.5, IPC 2018. | |||
| Entitlements | REVIEW COMPLETED | ||||
| External Reviewers - Arizona Department of Transportation (ADOT) | REVIEW COMPLETED | Re: URGENT PAST DUE ! PERMIT: CIP-0725-00017 Please Sign-In DUE: 12/11/2025 • 11/26/2025 2:39PM jgomes@azdot.gov on behalf of ADOT SC Traffic Engineering - ADOT CDRC Christian Niemi Good Morning, ADOT has no comments on this CIP. Thank you for the opportunity to review. |
|||
| External Reviewers - Pima Association of Governments | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required | |||
| External Reviewers - Southwest Gas | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required | |||
| External Reviewers - Tucson Electric Power (TEP) | REVIEW COMPLETED | Refer to CIP-1225-00029 | |||
| External Reviewers - United States Postal Service (USPS) | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required | |||
| Fire New Construction | REVIEW COMPLETED | ||||
| New Services/JOC | REVIEW COMPLETED | Tucson Water has no objections to this Development Package/Remodel | |||
| NPPO | REVIEW COMPLETED | See site landscape comments for NPPO comments. Thank you. Chad Keller, RLA chad.keller@tucsonaz.gov |
|||
| Outdoor Lighting | REVIEW COMPLETED | Include the outdoor lumen calculations on the final plans. | |||
| PDSD Application Completeness Express | REVIEW COMPLETED | ||||
| ROW Engineering Review | REVIEW COMPLETED | ||||
| Signs | REVIEW COMPLETED | ||||
| Site Engineering | REVIEW COMPLETED | ||||
| Site Landscape | REVIEW COMPLETED | PER COMMENT PROVIDED DURING A PRE APPLICATION MEETING (TP-PRE-0125-00017), FEBRUARY OF 2025, I STATED THE FOLLOWING. 1. Provide protective fencing at the drip line of the existing trees to the west of the new 571 SF addition. This will protect the tree roots from being compacted which could damage or kill the tree. 2. If the Mesquites are going to be removed due to this remodel, then please provide a NPPO or a NPPO Waiver with your next submittal. Mitigation for the two Mesquites may be required per the NPPO. Thank you. Chad Keller, RLA chad.keller@tucsonaz.gov |
|||
| Site Zoning | REVIEW COMPLETED | ||||
| TSMR/PDMR - Landscape | REVIEW COMPLETED | ||||
| TSMR/PDMR - Zoning | REVIEW COMPLETED | ||||
| TW Planning and Engineering Review | REVIEW COMPLETED | On sheet 6 of 7, Ref Note 7 states to protect the existing fire service is to be protected. Ref Note 18 states to "realign" to avoid conflict. Which note would be correct? If the fire service is to be realigned it would be problematic as there is no valve in place to turn off the fire service. A new design would have to reflect additional valves to meet SD-500 sheet 4. ***UPDATE*** Emailed G. Vega (Dibble). Engineer will field fit pad around existing Fire Service water line and change plan accordingly. Changing Status to "Review Completed" | |||
| Water - PDSD | REVIEW COMPLETED | Verify the size of the existing water meter and backflow preventer serving the building and provide the new total water demand. | |||
| Zoning Modifications - DDO | REVIEW COMPLETED | ||||
| Zoning Modifications - IPP | REVIEW COMPLETED | ||||
| Zoning Modifications - MS&R | REVIEW COMPLETED | ||||
| Zoning Modifications - Variance | REVIEW COMPLETED |