Plan: S01-038
Plan Details
Apply Date:
08/24/2001
Applicant:
PRESIDIO ENGINEERING INC
Description:
SUBC
Contractors:
- PRESIDIO ENGINEERING INC
Outstanding Plan Activity Conditions
Plan Number - S01-038
Plan Description: SUBC
| Date | Name | Approved | Comments |
|---|---|---|---|
| 09/20/2001 | CDRC TRANSMITTAL TO: Development Services Center FROM: David Rivera Plans Coordination Office Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: S01-038 Drexel Vistas, Lots 1-89 and Common Area "A" an RCP Tentative Plat TRANSMITTAL: September 19, 2001 DUE DATE: September 14, 2001 COMMENTS: First Review CODE SECTION/ DEVELOPMENT STANDARD 1. An applicant has one (1) year from the date of application to obtain approval of a tentative plat that complies with zoning and other development requirements in effect at the time of application. This tentative plat must be approved on or before August 24, 2002. LUC 4.1.7.1 2. This project has been assigned the following subdivision case number S01-038. Please list the subdivision case number in the right corner next to the title block of all tentative plat, landscape and, NPPO sheets. DS 2-03.2.2.B.1 3. Clarify if the common areas are specific to drainageway and detention basin purposes. If the common areas will be reserved for different use please provide a separate letter designation for each use and label the proposed use of the common area. DS 2-03.2.4.C 4. Revise the zoning classifications as follows. The zoning classification adjacent to the north is R-2, the zoning classification adjacent to the northeast portion of the site is R-2. DS 2-02.2.4.D 5. Per discussion with Craig Gross regarding the required street perimeter building setback for 12th Avenue, the existing right-of-way dimension (150 feet) and its future back of curb location must be used for the building set back for lots 1 and 56. Per the 150 feet cross section for a 150 feet right-of-way the future curb will be located 12 feet from the property line. Show graphically and dimension the future curb and sidewalks. The street perimeter building setbacks must be dimensioned form the back of the future curb location. The same is true for the street perimeter building setbacks from Drexel Road. The greater off the street perimeter or the interior building setback must be used. Show graphically and dimension the location of the future curb and sidewalks Liberty Avenue. The perimeter yard building setbacks for lots 34 - 50 must be based on the greater of 6' or 2/3 the building height. The minimum building setback for these lots will be three (3) feet where the required perimeter yard building setback falls within the common area. The perimeter yard building setback for lots 1-8 must be based on the height of the structure. The typical lot details must be revised to include this setback. The perimeter boundary setback dimensions must be shown graphically on the plat and must correspond to the information on the typical lot details. Revise as required. DS 2-03.2.4.M And DS 2-10.3. 6. Demonstrate how this RCP development is in compliance with the 12th Avenue/Valencia area plan. See Planning Department, Community Planning Section review comments. LUC 3.6.1.4.A.1 And DS 2-10.3.2.B 7. Please the typo in general 5. The density allowed for the RCP 9 Development Designator is 36 units per acre, DS 2-10.3.1.C 8. This site is within the Airport Hazards Zone. The MSLE of the site and of the end of the runway facing this subdivision must be listed on the plan. The elevations as shown on the AEZ overlay zone map which affect this site must be graphically shown on the plat. Provide a calculation, which demonstrates that, the highest point of the site plus the height of the tallest proposed structure. See LUC section 2.8.5.3. DS 2-03.2.2.B.7 9. Please ensure that any and all changes that are made to the tentative plat sheets are made to the corresponding landscape and NPPO sheets for consistency. 10. See comments regarding landscape borders, screening, and NPPO requirements. Please submit for review, revised blueline or reproducible copies along with the redline copies of the site plan. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. DGR: dgr: c:\planning\cdrc\tentativeplat\S01038tp.doc | Not Approved |