Permit: TS-PRM-0226-00068
Permit Details
Status:
Inspections Complete
Type:
Sign - Permanent
Address:
3605 E BROADWAY BL
Address NEW:
3605 E BROADWAY BL
Apply Date:
02/20/2026
Applicant:
Frank Andrade
Description:
Install four (4) int. Illum. channel wall signs 5’-0” x11’-9”; one (1) int. Illum. logo sign 5’-0” x5’-0; two (2) int. illum. directional signs 1’-2” x 2’-7”, 3’-0” (OAH); one (1) menu board; two (2) clearance arms
Permit Reviews
Permit Number - TS-PRM-0226-00068
Permit Status: Inspections complete
Permit Description: Install four (4) int. Illum. channel wall signs 5’-0” x11’-9”; one (1) int. Illum. logo sign 5’-0” x5’-0; two (2) int. illum. directional signs 1’-2” x 2’-7”, 3’-0” (OAH); one (1) menu board; two (2) clearance arms
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/23/2026 | PERMANENT SIGN REVIEW v.1 | 03/18/2026 | REQUIRES RESUBMIT |
| 05/13/2026 | PERMANENT SIGN REVIEW v.2 | 05/26/2026 | APPROVED |
Conditions
Permit Number - TS-PRM-0226-00068
Permit Status: Inspections complete
Permit Description: Install four (4) int. Illum. channel wall signs 5’-0” x11’-9”; one (1) int. Illum. logo sign 5’-0” x5’-0; two (2) int. illum. directional signs 1’-2” x 2’-7”, 3’-0” (OAH); one (1) menu board; two (2) clearance arms
| Date | Description | Comments |
|---|---|---|
| 06/10/2026 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TS-PRM-0226-00068
Permite Description: Install four (4) int. Illum. channel wall signs 5’-0” x11’-9”; one (1) int. Illum. logo sign 5’-0” x5’-0; two (2) int. illum. directional signs 1’-2” x 2’-7”, 3’-0” (OAH); one (1) menu board; two (2) clearance arms
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/19/2026 | COT - ENGR - Signage Final | N/A | Re-inspection required | 12-19-2026 UL sticker visible, Manufacturer sticker visible and shutoff switch visible on signage. Panel box is correctly labeled for signage. Proof is needed for timer of signage that signs go off at 11pm or at the end of business hours to comply with Tucson's outdoor lighting code. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TS-PRM-0226-00068
Permit Description: Install four (4) int. Illum. channel wall signs 5’-0” x11’-9”; one (1) int. Illum. logo sign 5’-0” x5’-0; two (2) int. illum. directional signs 1’-2” x 2’-7”, 3’-0” (OAH); one (1) menu board; two (2) clearance arms
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/19/2026 | COT - ENGR - Sign Electrical | Passed | 10-19-2026 UL label and Manufacturer sticker are visible and Shut off switch. | |
| 10/28/2026 | COT - ENGR - Signage Final | Passed | Contractor provided picture with a LCD showing time of 11:58 and labeled occupancy time clock. He is adamant that this is the timer that controls signage. I discussed the need for clearer labeling for future timers. |