Permit: TR-UTL-1225-02142
Permit Details
Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
1115 S PLUMER AV
Address NEW:
1115 S PLUMER AV
Apply Date:
12/11/2025
Applicant:
ANGEL MORALES
Description:
P.166688-KAHNA BORE 1869' & TRENCH 183' TO PLACE CONDUIT AND FIBER CABLE. PULL 53' OF NEW FIBER CABLE THROUGH EXISTING CONDUIT. PLACE 1398' OF AERIAL FIBER CABLE. PLACE 1 CABINET & 6 HAND HOLES
Permit Reviews
Permit Number - TR-UTL-1225-02142
Permit Status: Complete
Permit Description: P.166688-KAHNA
BORE 1869' & TRENCH 183' TO PLACE CONDUIT AND FIBER CABLE. PULL 53' OF NEW FIBER CABLE THROUGH EXISTING CONDUIT. PLACE 1398' OF AERIAL FIBER CABLE. PLACE 1 CABINET & 6 HAND HOLES
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/12/2025 | RIGHT-OF-WAY REVIEW v.1 | 12/16/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-1225-02142
Permit Status: Complete
Permit Description: P.166688-KAHNA
BORE 1869' & TRENCH 183' TO PLACE CONDUIT AND FIBER CABLE. PULL 53' OF NEW FIBER CABLE THROUGH EXISTING CONDUIT. PLACE 1398' OF AERIAL FIBER CABLE. PLACE 1 CABINET & 6 HAND HOLES
Total Outstanding Activity Conditions - 7
| Date | Name |
|---|---|
| 12/15/2025 | ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section |
| 12/15/2025 | Alley Restrictions Alley must be restored to existing or better condition. Alley surface must be graded and compacted to City Standards and Specifications for Public Improvements and existing drainage patterns must be restored and maintained. Any disturbed gravel must be replaced. |
| 12/15/2025 | City of Tucson Right of Way Only ROW Permit is only allowed for work within City of Tucson Right of Way. |
| 12/15/2025 | Pre-Activity Meeting w/Inspections Pre- activity meeting to be held 72 hrs in advance of work start with inspections.. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. |
| 12/15/2025 | Private Property Driveways and private property shall NOT be utilized without the owner’s consent. It is the contractor’s responsibility to negotiate use of private property. |
| 12/15/2025 | Traffic control set-up approved between 9AM - 3:30PM |
| 12/15/2025 | Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area. |
Completed Inspections
Permit Status: Complete
Permit Number: TR-UTL-1225-02142
Permit Description: P.166688-KAHNA
BORE 1869' & TRENCH 183' TO PLACE CONDUIT AND FIBER CABLE. PULL 53' OF NEW FIBER CABLE THROUGH EXISTING CONDUIT. PLACE 1398' OF AERIAL FIBER CABLE. PLACE 1 CABINET & 6 HAND HOLES
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/15/2026 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
| 01/26/2026 | TRSP - ROW - Barricade - Setup/Routine | Passed | ||
| 01/26/2026 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
| 04/03/2026 | TRSP - ROW - Final | Passed | All new poles arial attachments have been made and all underground boar shots have been made and cleaned up all work complete |