Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
2661 N 1ST AV
Address NEW:
2661 N 1ST AV
Apply Date:
12/23/2024
Applicant:
Cox Communications
Description:
Cox to aerial overlash 612' of ffiber and bore 98' to install conduit for system tie.

Permit Reviews

Permit Number - TR-UTL-1224-02409
Permit Status: Complete
Permit Description: Cox to aerial overlash 612' of ffiber and bore 98' to install conduit for system tie.
Start Date Submittal Complete Date Status  
12/24/2024 RIGHT-OF-WAY REVIEW v.1 12/27/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-UTL-1224-02409
Permit Status: Complete
Permit Description: Cox to aerial overlash 612' of ffiber and bore 98' to install conduit for system tie.
Total Outstanding Activity Conditions - 5
Date Name
12/27/2024 ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D.
12/27/2024 BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION.
12/27/2024 E. Kelso St is subject to a pavement moratorium. A 2-inch mill and overlay, covering half the width of the roadway, is required. The ROW inspector will confirm the treatment required for pavement restoration at the preconstruction meeting
12/27/2024 Traffic control set-up approved between 9AM - 3:30PM
12/27/2024 A NOTICE OF TEMPORARY HOLIDAY RESTRICTION applies to this permit and will be in effect from Thanksgiving Day to January 02. Due to the increasing traffic volume on many of the City’s roads, it is necessary to restrict lane closures on certain roads during the holiday season.

Completed Inspections

Permit Status: Complete
Permit Number: TR-UTL-1224-02409
Permit Description: Cox to aerial overlash 612' of ffiber and bore 98' to install conduit for system tie.
Total Completed Inspections - 4
Date Description Inspector Results Comments
02/05/2025 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Passed
02/14/2025 TRSP - ROW - Barricade Takedown Passed
02/14/2025 TRSP - ROW - Backfill - Placement/Compaction Passed
02/25/2025 TRSP - ROW - Final Passed

Documents

File Name Document Type  
COT - TR - ROW PERMIT.PDF DOCUMENTS VIEW
BI-522111_PRJ283750-1_2661 N 1ST AVE_TCP_V1.PDF DOCUMENTS VIEW
PRJ283750-1_TUCSON_V1.PDF DOCUMENTS VIEW