Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Apply Date:
12/19/2022
Applicant:
Adam Bishop
Description:
Related to PIA T22PI00014. Plan No. I-2022-017, Pima County Regional Wastewater Reclamation Department Silverbell Siphon Structure Replacement - near Silverbell Golf Course and Camino De Osete Wash on west-side of Santa Cruz River and River Park Drive on east-side of Santa Cruz River - plans from Pima County

Permit Reviews

Permit Number - TR-UTL-1222-00462
Permit Status: Complete
Permit Description: Related to PIA T22PI00014. Plan No. I-2022-017, Pima County Regional Wastewater Reclamation Department Silverbell Siphon Structure Replacement - near Silverbell Golf Course and Camino De Osete Wash on west-side of Santa Cruz River and River Park Drive on east-side of Santa Cruz River - plans from Pima County
Start Date Submittal Complete Date Status  
03/19/2023 RIGHT-OF-WAY REVIEW v.1 03/22/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-UTL-1222-00462
Permit Status: Complete
Permit Description: Related to PIA T22PI00014. Plan No. I-2022-017, Pima County Regional Wastewater Reclamation Department Silverbell Siphon Structure Replacement - near Silverbell Golf Course and Camino De Osete Wash on west-side of Santa Cruz River and River Park Drive on east-side of Santa Cruz River - plans from Pima County
Total Outstanding Activity Conditions - 1
Date Name
12/19/2022 Additional PIA conditions. 1. All construction Activities and Test methods shall be in conformance to the current edition of PAG Standard Specifications and Details for Public Improvements. https://apps.pagregion.com/standardspecifications/ 2. Material certificates of compliance for all materials must be submitted to the inspector at the time of material delivery. 3. Asphalt and concrete mix designs as well as ABC must be submitted to the Field Engineering Manager at PIAsubmittals@tucsonaz.gov for approval. Please allow for three weeks to review and approve. 4. Material Testing will be provided by City of Tucson (COT). 5. All work that that requires inspection such as formwork, sub-grade prep, backfill, etc. must be coordinated with the inspector PRIOR to beginning work. Work done without proper inspection will be rejected, removed, and replaced at no cost to the city. 6. The contractor will promptly inform the inspector of any plan discrepancies. Engineer of Record (EOR) is responsible for any major changes to the plans. 7. The contractor shall perform SWPP Best Management Practices. 8. Driveways and private property shall not be utilized without the owner’s consent. It is the contractor’s responsibility to negotiate use of private property. 9. The contractor shall always maintain construction site by a competent supervisor experienced in standard practices relating to public right-of-way construction. 10. The contractor shall coordinate the placing of any signage and stripping with COT Traffic Engineering. Contact Esther Cruz at (520) 334-8136 esther.cruz@tucsonaz.gov 11. Prior to disturbing COT owned irrigation Contact Shawn Moore at (520) 820-2945 shawn.moore@tucsonaz.gov 12. Prior to disturbing any landscaping/vegetation in the right-of-way Contact David Marhefka at (520) 403-5074 david.marhefka@tucsonaz.gov 13. Prior to disturbing or installing street lighting or traffic signal equipment. The contractor shall contact and coordinate work with the COT Electric Shop. Contact Robert Stineman (520) 484-4067 Robert.Stineman@tucsonaz.gov & Armando Bracamonte (520) 791-3191 Armando.Bracamonte@tucsonaz.gov If any shop drawings are required, they will need to be submitted for review 3 weeks in advance. 14. Temporary Traffic Control shall be provided per the current MUTCD and City and State supplements. It is the contractor’s responsibility to maintain traffic control per the approved plans. Any changes to the approved traffic control plan needs to be resubmitted for approval. 15. Coordinate with City inspector for any City owned materials that will be salvage. 16. When construction is near completion, coordinate with inspector for walkthrough and approval. After acceptance, submit Record Document with signatures and final acceptance date to DOT-Engineering-Review-Section@tucsonaz.gov. Record Document (As-Built) drawings are the responsibility of the EOR, Line, grade and major changes must be noted on the original mylar plan set. Please allow COT Maps and Records for 2-3 weeks to review. 17. Applicant shall guarantee work against defective materials or workmanship for a period of one year minimum from the final acceptance date.

Outstanding Inspections

Permit Status: Complete
Permit Number: TR-UTL-1222-00462
Permite Description: Related to PIA T22PI00014. Plan No. I-2022-017, Pima County Regional Wastewater Reclamation Department Silverbell Siphon Structure Replacement - near Silverbell Golf Course and Camino De Osete Wash on west-side of Santa Cruz River and River Park Drive on east-side of Santa Cruz River - plans from Pima County
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
02/06/2023 TRSP - ROW - Recurring N/A Re-inspection required No activity

Completed Inspections

Permit Status: Complete
Permit Number: TR-UTL-1222-00462
Permit Description: Related to PIA T22PI00014. Plan No. I-2022-017, Pima County Regional Wastewater Reclamation Department Silverbell Siphon Structure Replacement - near Silverbell Golf Course and Camino De Osete Wash on west-side of Santa Cruz River and River Park Drive on east-side of Santa Cruz River - plans from Pima County
Total Completed Inspections - 1
Date Description Inspector Results Comments
12/22/2022 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Passed Preconstruction Meeting for PIA complete.

Documents

File Name Document Type  
HUNTER RIVERPARK DR._V1.PDF DOCUMENTS VIEW
SIPHON STRUCTURE WORK AREA_V1.PDF DOCUMENTS VIEW
TCP 3001 N DASYLIRION DR._V1.PDF DOCUMENTS VIEW
COT - TR - ROW PERMIT.PDF DOCUMENTS VIEW