Permit: TR-UTL-1126-01939
Permit Details
Status:
Fees Due
Type:
Right-of-Way (ROW) - Utility
Address:
8690 E BROADWAY BL
Address NEW:
8690 E BROADWAY BL
Apply Date:
11/10/2026
Applicant:
Angeline Trejo
Description:
Access to one handhole for fiber optic cable placing & splicing. Place 280’ of aerial fiber cable; trench 20’ and place innerduct and fiber cable. This project is for Lumen and will not be conveyed to any other company.
Permit Reviews
Permit Number - TR-UTL-1126-01939
Permit Status: Fees due
Permit Description: Access to one handhole for fiber optic cable placing & splicing. Place 280’ of aerial fiber cable; trench 20’ and place innerduct and fiber cable. This project is for Lumen and will not be conveyed to any other company.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/12/2026 | RIGHT-OF-WAY REVIEW v.1 | 11/17/2026 | REQUIRES RESUBMIT |
| 11/18/2026 | RIGHT-OF-WAY REVIEW v.2 | 11/19/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-1126-01939
Permit Status: Fees due
Permit Description: Access to one handhole for fiber optic cable placing & splicing. Place 280’ of aerial fiber cable; trench 20’ and place innerduct and fiber cable. This project is for Lumen and will not be conveyed to any other company.
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 11/16/2026 | Bus stop in the area, contact Joe Garcia, Sun Tran Dispatch, at 520-576-8726 at least 48-business hours prior to start of work for coordination |
| 11/16/2026 | **Pre-Activity Meeting w/Inspections **Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 – 42 Refer to COT 2015 Addition to the MUTCD section 14 |
| 11/16/2026 | Traffic control set-up approved between 9AM - 3:30PM |
| 11/19/2026 | Lane closures shall only be permitted during active work operations. At the end of each workday, the contractor shall remove all traffic control devices and reopen the roadway, bike lanes, and sidewalks to normal operation. Twenty-four (24) hour lane closures are not permitted unless specifically approved by the City. Traffic Control Devices shall not be stored in the bike lane or sidewalk - The contractor shall restore all disturbed pavement in accordance with the City of Tucson Standard Specifications for Public Improvements and applicable standard details. All pavement patches shall match the existing pavement section and surface condition. The contractor shall maintain all temporary patches in a safe and drivable condition until permanent restoration is completed. Any settlement, cracking, or pavement failure within the patched area shall be repaired by the contractor at no cost to the City for the duration of the warranty period |
| 11/19/2026 | Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section 14 |