Permit Details

Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address NEW:
6541 E FAYETTE ST
Apply Date:
11/01/2023
Applicant:
Cameron Bonner
Description:
323035 Site 2 and 3 - Install Approximately 521 LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars and manhole bench rehabilitation will be completed on MH's 7250-03, 7250-02, and 7250-01 per PCRWRD standard detail 211

Permit Reviews

Permit Number - TR-UTL-1123-02855
Permit Status: Complete
Permit Description: 323035 Site 2 and 3 - Install Approximately 521 LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars and manhole bench rehabilitation will be completed on MH's 7250-03, 7250-02, and 7250-01 per PCRWRD standard detail 211
Start Date Submittal Complete Date Status  
11/03/2023 RIGHT-OF-WAY REVIEW v.2 11/08/2023 APPROVED Review Details
11/01/2023 RIGHT-OF-WAY REVIEW v.1 11/02/2023 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TR-UTL-1123-02855
Permit Status: Complete
Permit Description: 323035 Site 2 and 3 - Install Approximately 521 LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars and manhole bench rehabilitation will be completed on MH's 7250-03, 7250-02, and 7250-01 per PCRWRD standard detail 211
Total Outstanding Activity Conditions - 2
Date Name
11/02/2023 Traffic Control set-up approved between 7AM - 5PM
11/08/2023 Your project work requires that you contact City of Tucson Environmental Services Department (520-791-3171) at least 24 hours prior to closing any street or alley.

Completed Inspections

Permit Status: Complete
Permit Number: TR-UTL-1123-02855
Permit Description: 323035 Site 2 and 3 - Install Approximately 521 LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars and manhole bench rehabilitation will be completed on MH's 7250-03, 7250-02, and 7250-01 per PCRWRD standard detail 211
Total Completed Inspections - 1
Date Description Inspector Results Comments
03/14/2024 TRSP - ROW - Notice of Completion Passed

Documents

File Name Document Type  
COT - TR - ROW PERMIT.PDF DOCUMENTS VIEW
323035 - SITE 2 AND 3 FMP MAP (6541 E FAYETTE ST) - 1_V1.PDF DOCUMENTS VIEW
DB 68615 - PAGE 2 - 6541 E FAYETTE ST. - FOOTBALL - BUMPOUT REV 1- 323035_V1.PDF DOCUMENTS VIEW