Permit: TR-UTL-1026-01809
Permit Details
Status:
Fees Paid
Type:
Right-of-Way (ROW) - Utility
Address:
400 S BROADWAY PL
Address NEW:
400 S BROADWAY PL
Apply Date:
10/19/2026
Applicant:
Cox Communications
Description:
PRJ323780-1: Cox to overlash 929' of existing CATV aerial strand, pull thru 311' of existing CATV conduit & remove/ replace existing ped with vaulted ped, then continue pull thru onto private property for system tie.
Permit Reviews
Permit Number - TR-UTL-1026-01809
Permit Status: Fees paid
Permit Description: PRJ323780-1: Cox to overlash 929' of existing CATV aerial strand, pull thru 311' of existing CATV conduit & remove/ replace existing ped with vaulted ped, then continue pull thru onto private property for system tie.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/21/2026 | RIGHT-OF-WAY REVIEW v.1 | 10/26/2026 | REQUIRES RESUBMIT |
| 11/18/2026 | RIGHT-OF-WAY REVIEW v.3 | 11/18/2026 | APPROVED |
| 11/13/2026 | RIGHT-OF-WAY REVIEW v.2 | 11/13/2026 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TR-UTL-1026-01809
Permit Status: Fees paid
Permit Description: PRJ323780-1: Cox to overlash 929' of existing CATV aerial strand, pull thru 311' of existing CATV conduit & remove/ replace existing ped with vaulted ped, then continue pull thru onto private property for system tie.
Total Outstanding Activity Conditions - 7
| Date | Name |
|---|---|
| 10/21/2026 | Alley must be restored to existing or better condition. Alley surface must be graded and compacted to City Standards and Specifications for Public Improvement and existing drainage patterns must be restored and maintained. Any disturbed gravel must be replaced. |
| 10/21/2026 | Traffic control set-up approved between 9AM - 3:30PM |
| 11/18/2026 | Bike Lane Access and Accommodation 1) Posted Speeds 30 Mph or Less – Less than 14 lane - Use of the R4-11 alone is acceptable and preferred over Share The Road sign - 2) Posted Speeds 30 Mph or less – greater than 14 lane - Use of Share The Road sign is preferred 3) Posted Speeds 30 Mph or More – Any Lane Size - Provide a reasonable alternative for cyclists, such as a paved path, space behind barricades, or bike detour. Acceptable to direct cyclists to the sidewalk when properly signed depending on conditions 4) Bike lane to be maintained within Traffic Control closure and Share may Pedestrian detour path with proper R9-6 Sign. |
| 11/18/2026 | No pedestrian detour is proposed; therefore, the sidewalk shall always remain open and ADA-compliant during construction. TC Company -assisted pedestrian access does not constitute a pedestrian detour and shall not require pedestrians to leave the designated pedestrian path. If the sidewalk cannot be maintained in an open and ADA-compliant condition, an approved pedestrian detour shall be implemented prior to any sidewalk closure. |
| 11/18/2026 | Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section 14 |
| 11/18/2026 | Pre-Activity Meeting w/Inspections Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. |
| 11/18/2026 | Notify in writing at least 5 working days before work begins, any businesses, residences and public transit routes affected by your temporary traffic control. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. |