Permit: TR-UTL-1026-01794
Permit Details
Apply Date:
10/16/2026
Applicant:
Alex Dietz
Description:
JO 326X013 Sites 1 and 2 - Site 1: Remove cleanout 2753*01 and install new terminal manhole to allow the installation of Approximately 141 LF of 8" Cured in Place Pipe between the new terminal manhole and MH 2753-02. Site 2: Remove cleanout 2753*02 and install new terminal manhole to allow the installation of approximately 141 LF of 8" Cured in Place Pipe between the new terminal manhole and MH 2753-03. Rehab entire MH bench for MH 2753-02 and 2753-03 per PCRWRD Standard Specifications and Details for Construction Std. 302. Install concrete collars on MH 2753-02 and MH 2753-03 per PCRWRD Standard Specifications and Details for Construction Std. 211.
Permit Reviews
Permit Number - TR-UTL-1026-01794
Permit Status: Issued
Permit Description: JO 326X013 Sites 1 and 2 - Site 1: Remove cleanout 2753*01 and install new terminal manhole to allow the installation of Approximately 141 LF of 8" Cured in Place Pipe between the new terminal manhole and MH 2753-02. Site 2: Remove cleanout 2753*02 and install new terminal manhole to allow the installation of approximately 141 LF of 8" Cured in Place Pipe between the new terminal manhole and MH 2753-03. Rehab entire MH bench for MH 2753-02 and 2753-03 per PCRWRD Standard Specifications and Details for Construction Std. 302. Install concrete collars on MH 2753-02 and MH 2753-03 per PCRWRD Standard Specifications and Details for Construction Std. 211.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/19/2026 | RIGHT-OF-WAY REVIEW v.1 | 10/23/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-1026-01794
Permit Status: Issued
Permit Description: JO 326X013 Sites 1 and 2 - Site 1: Remove cleanout 2753*01 and install new terminal manhole to allow the installation of Approximately 141 LF of 8" Cured in Place Pipe between the new terminal manhole and MH 2753-02. Site 2: Remove cleanout 2753*02 and install new terminal manhole to allow the installation of approximately 141 LF of 8" Cured in Place Pipe between the new terminal manhole and MH 2753-03. Rehab entire MH bench for MH 2753-02 and 2753-03 per PCRWRD Standard Specifications and Details for Construction Std. 302. Install concrete collars on MH 2753-02 and MH 2753-03 per PCRWRD Standard Specifications and Details for Construction Std. 211.
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 10/20/2026 | Notify in writing at least 5 working days before work begins, any businesses, residences and public transit routes affected by your temporary traffic control. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. |
| 10/20/2026 | Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. |
| 10/20/2026 | Traffic Control set-up approved between 7AM - 5PM |
| 10/22/2026 | Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area. |