Permit Details

Status:
Fees Paid
Type:
Right-of-Way (ROW) - Utility
Address NEW:
1909 S CRAYCROFT RD
Apply Date:
10/02/2026
Applicant:
Arnulfo Quiroz
Description:
T169928 - Replace (17) existing TEP/TELCO distribution poles, (6) downguys, OH conductors, OH attachments, and OH transformers in alleyways. Install (2) down guy assembly. Remove (1) TEP pole, OH conductors, and attachments. All to meet current TEP standards per Memo 2025C025- CORBETT NEIGHBORHOOD.

Permit Reviews

Permit Number - TR-UTL-1026-01720
Permit Status: Fees paid
Permit Description: T169928 - Replace (17) existing TEP/TELCO distribution poles, (6) downguys, OH conductors, OH attachments, and OH transformers in alleyways. Install (2) down guy assembly. Remove (1) TEP pole, OH conductors, and attachments. All to meet current TEP standards per Memo 2025C025- CORBETT NEIGHBORHOOD.
Start Date Submittal Complete Date Status  
11/02/2026 RIGHT-OF-WAY REVIEW v.2 11/04/2026 REQUIRES RESUBMIT Review Details
11/18/2026 RIGHT-OF-WAY REVIEW v.3 11/18/2026 APPROVED Review Details
10/05/2026 RIGHT-OF-WAY REVIEW v.1 10/26/2026 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TR-UTL-1026-01720
Permit Status: Fees paid
Permit Description: T169928 - Replace (17) existing TEP/TELCO distribution poles, (6) downguys, OH conductors, OH attachments, and OH transformers in alleyways. Install (2) down guy assembly. Remove (1) TEP pole, OH conductors, and attachments. All to meet current TEP standards per Memo 2025C025- CORBETT NEIGHBORHOOD.
Total Outstanding Activity Conditions - 7
Date Name
10/08/2026 Alley must be restored to existing or better condition. Alley surface must be graded and compacted to City Standards and Specifications for Public Improvements and existing drainage patterns must be restored and maintained. Any disturbed gravel must be replaced.
10/08/2026 Notify in writing at least 5 working days before work begins, any businesses, residences and public transit routes affected by your temporary traffic control. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING.
10/08/2026 Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online.
10/08/2026 Traffic control set-up approved between 9AM - 3:30PM
11/04/2026 Lane closures shall only be permitted during active work operations. At the end of each workday, the contractor shall remove all traffic control devices and reopen the roadway, bike lanes, and sidewalks to normal operation. Twenty-four (24) hour lane closures are not permitted unless specifically approved by the City. Traffic Control Devices shall not be stored in the bike lane or sidewalk
11/04/2026 Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section 14
11/04/2026 Traffic Control set-up approved between 7AM - 5PM

Documents

File Name Document Type  
DB 73171 - 1909 S CRAYCROFT RD - VARIOUS - T169928 - PAGE2_V1.PDF DOCUMENTS VIEW
DB 73171 - 1909 S CRAYCROFT RD - VARIOUS - T169928_V1.PDF DOCUMENTS VIEW
DESIGN PLAN-AERIAL PERMIT MAP_T169928 - V3-D1_V1.PDF DOCUMENTS VIEW