Permit: TR-UTL-1025-01774
Permit Details
Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
6761 E TANQUE VERDE RD
Address NEW:
6761 E TANQUE VERDE RD
Apply Date:
10/10/2025
Applicant:
John Rhodes
Description:
Tie point will be existing coax aerial plant on utility pole. Overlash 500' of 48ct fiber over 2 spans. Place new riser. Bore 150' of 2" conduit at a depth of 3", run 150' of 48ct fiber. Bore 80' of 2" conduit at a depth of 3", run 80' of 48ct fiber.
Permit Reviews
Permit Number - TR-UTL-1025-01774
Permit Status: Complete
Permit Description: Tie point will be existing coax aerial plant on utility pole. Overlash 500' of 48ct fiber over 2 spans. Place new riser. Bore 150' of 2" conduit at a depth of 3", run 150' of 48ct fiber. Bore 80' of 2" conduit at a depth of 3", run 80' of 48ct fiber.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/10/2025 | RIGHT-OF-WAY REVIEW v.1 | 10/14/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-1025-01774
Permit Status: Complete
Permit Description: Tie point will be existing coax aerial plant on utility pole. Overlash 500' of 48ct fiber over 2 spans. Place new riser. Bore 150' of 2" conduit at a depth of 3", run 150' of 48ct fiber. Bore 80' of 2" conduit at a depth of 3", run 80' of 48ct fiber.
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 10/13/2025 | ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D. |
| 10/13/2025 | Bike Lane Access and Accommodation 1) Posted Speeds 30 Mph or Less – Less than 14 lane - Use of the R4-11 alone is acceptable and preferred over Share The Road sign - 2) Posted Speeds 30 Mph or less – greater than 14 lane - Use of Share The Road sign is preferred 3) Posted Speeds 30 Mph or More – Any Lane Size - Provide a reasonable alternative for cyclists, such as a paved path, space behind barricades, or bike detour. Acceptable to direct cyclists to the sidewalk when properly signed depending on conditions |
| 10/13/2025 | BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION. |
| 10/13/2025 | Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section 14 |
| 10/13/2025 | Pre-Activity Meeting w/Inspections Pre- activity meeting to be held 72 hrs in advance of work start with inspections.. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. |
| 10/13/2025 | Traffic control set-up approved between 9AM - 3:30PM |
Completed Inspections
Permit Status: Complete
Permit Number: TR-UTL-1025-01774
Permit Description: Tie point will be existing coax aerial plant on utility pole. Overlash 500' of 48ct fiber over 2 spans. Place new riser. Bore 150' of 2" conduit at a depth of 3", run 150' of 48ct fiber. Bore 80' of 2" conduit at a depth of 3", run 80' of 48ct fiber.
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/02/2025 | TRSP - ROW - Barricade - Setup/Routine | Passed | ||
| 12/02/2025 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
| 12/02/2025 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
| 12/02/2025 | TRSP - ROW - Final | Passed |