Permit: TR-UTL-1023-02739
Permit Details
Apply Date:
10/20/2023
Applicant:
Jaime Rivera
Description:
3230X8 Site 1 and 2 - Install Approximately 604 LF of 12" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. Manhole bench rehabilitation will be completed on MH's 8139-22 and MH 6864-01 per PCRWRD STD DTL. 302
Permit Reviews
Permit Number - TR-UTL-1023-02739
Permit Status: Complete
Permit Description: 3230X8 Site 1 and 2 - Install Approximately 604 LF of 12" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. Manhole bench rehabilitation will be completed on MH's 8139-22 and MH 6864-01 per PCRWRD STD DTL. 302
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/23/2023 | RIGHT-OF-WAY REVIEW v.3 | 10/24/2023 | REQUIRES RESUBMIT |
12/04/2023 | RIGHT-OF-WAY REVIEW v.2 | 12/06/2023 | APPROVED |
12/01/2023 | RIGHT-OF-WAY REVIEW v.1 | 12/01/2023 | REQUIRES RESUBMIT |
10/24/2023 | RIGHT-OF-WAY REVIEW v.4 | 11/02/2023 | APPROVED |
10/20/2023 | RIGHT-OF-WAY REVIEW v.1 | 10/20/2023 | REQUIRES RESUBMIT |
10/20/2023 | RIGHT-OF-WAY REVIEW v.2 | 10/20/2023 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TR-UTL-1023-02739
Permit Status: Complete
Permit Description: 3230X8 Site 1 and 2 - Install Approximately 604 LF of 12" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. Manhole bench rehabilitation will be completed on MH's 8139-22 and MH 6864-01 per PCRWRD STD DTL. 302
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
10/23/2023 | Traffic control set-up approved between 9AM - 3:30PM |
10/23/2023 | PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 |
Outstanding Inspections
Permit Status: Complete
Permit Number: TR-UTL-1023-02739
Permite Description: 3230X8 Site 1 and 2 - Install Approximately 604 LF of 12" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. Manhole bench rehabilitation will be completed on MH's 8139-22 and MH 6864-01 per PCRWRD STD DTL. 302
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/15/2023 | TRSP - ROW - Recurring | N/A | Partial Pass |
Completed Inspections
Permit Status: Complete
Permit Number: TR-UTL-1023-02739
Permit Description: 3230X8 Site 1 and 2 - Install Approximately 604 LF of 12" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. Manhole bench rehabilitation will be completed on MH's 8139-22 and MH 6864-01 per PCRWRD STD DTL. 302
Total Completed Inspections - 2
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/15/2023 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
12/28/2023 | TRSP - ROW - Final/Close-Out | Passed |