Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Apply Date:
10/20/2023
Applicant:
Cameron Bonner
Description:
323028 Site 1 - Reach has a sever sag in the line: Remove and replace 60LF of 8" pipe to correct the slope of the sewer line starting at 140LF from MH 9578-05. Install Approximately 285 LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars and manhole bench rehabilitation will be completed on MH's 9578-05 and MH 9591-5-H per PCRWRD standard detail 211

Permit Reviews

Permit Number - TR-UTL-1023-02736
Permit Status: Complete
Permit Description: 323028 Site 1 - Reach has a sever sag in the line: Remove and replace 60LF of 8" pipe to correct the slope of the sewer line starting at 140LF from MH 9578-05. Install Approximately 285 LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars and manhole bench rehabilitation will be completed on MH's 9578-05 and MH 9591-5-H per PCRWRD standard detail 211
Start Date Submittal Complete Date Status  
10/20/2023 RIGHT-OF-WAY REVIEW v.1 10/24/2023 APPROVED Review Details

Conditions

Permit Number - TR-UTL-1023-02736
Permit Status: Complete
Permit Description: 323028 Site 1 - Reach has a sever sag in the line: Remove and replace 60LF of 8" pipe to correct the slope of the sewer line starting at 140LF from MH 9578-05. Install Approximately 285 LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars and manhole bench rehabilitation will be completed on MH's 9578-05 and MH 9591-5-H per PCRWRD standard detail 211
Date Description Comments
10/20/2023 ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUAL. **SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D.
10/20/2023 Traffic Control set-up approved between 7AM - 5PM

Completed Inspections

Permit Status: Complete
Permit Number: TR-UTL-1023-02736
Permit Description: 323028 Site 1 - Reach has a sever sag in the line: Remove and replace 60LF of 8" pipe to correct the slope of the sewer line starting at 140LF from MH 9578-05. Install Approximately 285 LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars and manhole bench rehabilitation will be completed on MH's 9578-05 and MH 9591-5-H per PCRWRD standard detail 211
Total Completed Inspections - 2
Date Description Inspector Results Comments
10/31/2023 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Passed
01/23/2024 TRSP - ROW - Final/Close-Out Passed

Documents

File Name Document Type  
COT - TR - ROW PERMIT.PDF DOCUMENTS VIEW
323028 - SITE 1 FMP MAP (3525 S AVENIDA DE LAS PALMAS)_V1.PDF DOCUMENTS VIEW
DB 68360 - PAGE 1 - 3525 S AVENIDA DE LAS PALMAS - BUMPOUTS - FULL CLOSURE - 3525 - 3230X6_V1.PDF DOCUMENTS VIEW